Chapter 5:  Communication Jumper Settings 
 
This chapter will cover all of the jumper settings to set your B&B 
Serial Card for the proper communications that you desire. 
 
  
RS-232 Mode 
 
To configure a port for RS-232 mode, 5 jumpers must be 
checked. The following settings will configure Port 1 as RS-232. 
1.  JP1A - must be set in the "232" (left) position. 
2.  JP1F - all four jumpers must be set in the "232" (left) position. 
 
Jumpers JP1B - JP1E have no meaning in RS-232 mode 
and may be in either position.  Figure 2 shows the jumper 
configuration to set both ports for RS-232 mode.   
 
Figure 2.  RS-232 Mode Jumper Settings 
 
CAUTION: Electrostatic Sensitive Device. 
Use ESD precautions for safe handling. 
36  
Documentation 
No.3PXCC1x-2x-3903 
B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 
 RS-422 Mode 
 
To configure a port for RS-422 mode, 7 jumpers must be 
checked. The following settings configure Port 1 as RS-422. 
1. 
JP1A, JP1B, JP1C - must be set in the "422" (right) position. 
2. 
JP1F - all four jumpers must be in the "422" (right) position. 
 
Figure 3 shows the jumper configuration to set both ports for 
RS-422 mode.   
Figure 3.  RS-422 Mode Jumper Settings 
 
Note that the EIA RS-422 Specification labels data lines with 
an "A" and "B" designator. Some RS-422 equipment uses a "+" and 
"-" designator.  In almost all cases, the "A" line is the equivalent of 
the "-" line and the "B" line is the equivalent of the "+" line.  More 
information on RS-422 communications can be found in B&B 
Electronics’ free RS-422/RS-485 Application Note. 
RS-485 Mode 
 
To configure a port for RS-485 mode, 9 jumpers must be 
checked.  The following settings configure Port 1 as RS-485. 
1.  JP1A - must be set in the "422" (right) position. 
2.  JP1B, JP1C - must be set in the "485" (left) position. 
3.   JP1D, JP1E - set to match software and installation 
requirements. 
4.  JP1F - all four jumpers must be in the "422" (right) position.