Brocade Communications Systems Brocade MLX Series and Brocade Netlron XMR 53-1002373-02 Manual De Usuario

Descargar
Página de 452
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
337
53-1002373-02
Managing the cooling system
7
Displaying fan tray status and speed
To display the status and speed of the 4-speed fans in the router, enter the show chassis command 
at any level of the CLI.
Brocade# show chassis
...
--- FANS ---
Back fan tray 1: Status = OK, Speed = LOW (50%)
Back fan tray 2: Status = OK, Speed = LOW (50%)
Back fan tray 3: Status = OK, Speed = LOW (50%)
Back fan tray 4: Status = OK, Speed = LOW (50%)
Syntax: show chassis
For information about all output generated by the show chassis command, refer to 
Displaying temperature warnings 
If the temperature of a module exceeds the high temperature threshold for any of the fan speeds, 
the system sends a warning message to the system log and an SNMP trap. (For more information 
about the low and high temperature thresholds, refer to 
 on page 331.) This section describes how to view the system log. If you 
have configured your router to use a Syslog server or SNMP trap receiver, refer to the 
documentation for the server or receiver. 
To display the system log, enter the show log command at any CLI level.
Brocade# show log
Syntax: show log
Temperature log reduction
Depending on settings and temperature readings, fan speeds are changed dynamically within the 
following ranges: low, med, med-hi, and high. Fan speed changes are determined by temperature 
thresholds set for sensors on the management modules, interface modules and switch fabric 
modules. When a temperature threshold is passed upward on any module, the fan speed changes 
to the assigned fan speed. This occurs even if the temperature is within the threshold for the slower 
fan speed on other modules. In previous versions of the software, a log message is sent whenever 
a temperature threshold is crossed on any module whether the fan speed is actually increased or 
not. This can result in excessive log messages.
TABLE 51
Fan status and speed fields 
Field
Description
Status
The status can be one of the following:
OK – The fan is functioning properly and is keeping the temperature of each module within 
an acceptable temperature range.
Failed – The fan is not functioning properly or the fan control module cannot control the fan.
Speed
The speed can be one of the following:
LOW – The fan is functioning at 50 percent of capacity.
MEDIUM – The fan is functioning at 75 percent of capacity.
MEDIUM-HIGH – The fan is functioning at 90 percent of capacity.
HIGH – The fan is functioning at 100 percent of capacity.