Hardware specifications for Brocade NetIron XMR routers
9
Safety agency approvals
CAN/CSA-C22.2 No. 60950-1-07/UL60950-1 – Second Edition, Safety of Information 
Technology Equipment
EN 60825-1 Safety of Laser Products – Part 1: Equipment Classification, Requirements and 
User’s Guide
EN 60825-2 Safety of Laser Products – Part 2: Safety of Optical Fibre Communications 
Systems
EN 60950-1:2006\IEC 60950-1:2005, Second Edition, Safety of Information Technology 
Equipment
Electromagnetic approvals
FCC Part 15, Subpart B (Class A) 
EN 55022 (CE mark) (Class A) 
EN 55024 (CE mark) (Immunity) for Information Technology Equipment 
ICES-003 (Canada) (Class A) 
AS/NZ 55022 (Australia) (Class A) 
VCCI (Japan) (Class A) 
EN 61000-3-2 
EN 61000-3-3 
EN 61000-6-1 
Hardware specifications for Brocade NetIron XMR routers
The following sections describe hardware specifications for Brocade NetIron XMR routers.
Power specifications
The following power supply frequency requirements apply to Brocade NetIron XMR 4000, 8000, 
and 16000 routers:
AC Input Rating: 100 to 240V, 50/60 Hz, 16.0 A maximum per power supply
AC Operating Voltage Range: 90 - 264V, 50/60 Hz
Inrush current: 40A peak maximum at 25 degrees C (77 degrees F)
DC Input Rating: -48V, 30.0 A maximum per power supply
DC Operating Range: -40 to -60V
Inrush current: 45A peak maximum at 25 degrees C (77 degrees F)
The following power supply frequency requirements apply to Brocade NetIron XMR 32000 routers:
AC Input Rating: 200 -240V, 50/60 Hz, 16.0 A maximum per power supply
AC Operating Voltage Range: 180-264V
Inrush current: 30A peak maximum at 25 degrees C (77 degrees F)
DC Input Rating: -48V, 60.0 A maximum per power supply
DC Operating Range: -40 to -60V