Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
67
53-1002373-02
Installing 2x100GbE interface modules in Brocade MLXe routers
2
CAUTION
For the NEBS-compliant installation of Brocade MLXe-4, Brocade MLXe--8, and Brocade MLXe-16 
routers with AC and DC systems, use a ground wire of at least 6 American Wire Gauge (AWG). The 
ground wire should have an agency-approved crimped connector (provided with the device) 
attached to one end, with the other end attached to building ground. The connector must be 
crimped with the proper tool, allowing it to be connected to both ground screws on the enclosure. 
Before crimping the ground wire into the provided ground lug, ensure the bare copper wire has 
been cleaned and antioxidant is applied to the bare wire.
CAUTION
For the NEBS-compliant installation of Brocade MLXe-32, routers with AC and DC systems, use a 
ground wire of at least 2 American Wire Gauge (AWG). The ground wire should have an 
agency-approved crimped connector (provided with the device) attached to one end, with the 
other end attached to building ground. The connector must be crimped with the proper tool, 
allowing it to be connected to both ground screws on the enclosure. Before crimping the ground 
wire into the provided ground lug, ensure the bare copper wire has been cleaned and antioxidant 
is applied to the bare wire.
Installing 2x100GbE interface modules in Brocade MLXe routers
This section provides installation instructions for 2x100G interface modules.
Installation considerations
2x100G interface modules cannot be installed in slot 1 of a Brocade MLX 4-slot or a Brocade 
NetIron XMR4000 chassis. This restriction does not apply to Brocade MLXe 4-slot devices.
2x100G modules occupy two adjacent slots. When you install a 2x100G module, the odd 
numbered (low number) slot of the slot pair becomes the active slot, and the even numbered 
slot (higher number) is blocked.
The acceptable slots in which to install this module are odd-numbered interface module slots 
(1, 3, 5, 7, 9. 11, 13, and 15 for a 16-slot chassis, for example). Adjacent even-numbered slots 
will be in blocked state. In all cases, the lower number (odd number) becomes the active slot 
and the higher number (even number) becomes the blocked slot.
2x100G modules cannot be installed in the following scenarios:
-
If there is another type of module installed in either of the slots
-
If either slot is configured as something else. Before you install your 2x100G module, you 
will need to reconfigure the slot using the no module command.
The following conditions will prevent a 2x100G interface module from operating properly:
-
If either of the two slots required to house the module is already configured for another 
type of module.