Brocade Adapters Administrator’s Guide
137
53-1001583-01
diag
B
diag 
Lists the non-destructive group of diagnostic commands. The port can be identified using the 
adapter index, the port index, the port name, or the port world wide name.
NOTE
The sfpshow and beacon diag commands are not supported on the Brocade 804 mezzanine card.
Synopsis
bcu diag --sfpshow <port_id
bcu diag --tempshow [ad_id
bcu diag --beacon <port_id> {on | off} [<secs>] 
bcu diag --pciloopback <port_id> <-p <pattern> [-c <frame_count>]
bcu diag --loopback <port_id> [-t <loopback_type>] [-s <speed>] [-c <frame_count>] 
[-p <pattern>] 
bcu diag --memtest <port_id
bcu diag --queuetest <port_id> [-q <queue_num>]
Description
Displays the group of diagnostic commands that are non-destructive and indicates when the 
adapter is running at a normal operation state.
NOTE
You must disable the port prior to executing the loopback test. You must disable the adapter prior to 
executing the memtest.
Operands
--sfpshow
Monitors the attributes of the SFP. This is an online diagnostic test. 
Note: A notification occurs for any parameter that is not within the configured 
power, temperature, voltage, and current specification or policy.
port_id
Specifies the ID of the port on which you want to monitor the SFP attributes.
--tempshow
Reads the adapter’s temperature sensor registers of the adapter. This is an 
online diagnostic test.
ad_id
Specifies the ID of the adapter for which you want to display temperature 
sensor registers. 
--beacon
Controls the port and link end-to-end beaconing. This is an online diagnostic 
test.
port_id
Specifies the ID of the port for which you want to beacon.
on | off
Turns end-to-end beaconing on or off.
secs
Displays the beacon time duration in seconds. Beaconing is automatically 
turned off after the specified duration. If the duration is set to 0, beaconing 
continues until it is explicitly turned off.