Bradford-White Corp PE4403S*F(BN,SX) Manual De Usuario

Descargar
Página de 32
 Page 29 
Relay Replacement (cont’d) 
Step 3. 
Remove the (2) screws holding the Setback Control 
Junction Box Assembly cover on and retain for later use. 
Step 4. 
Mark the (4) wires that are attached to the relay, so 
their proper location is known. 
Step 5. 
Disconnect the (4) wires attached to the relay. 
Step 6. 
Remove the relay from its socket. 
Step 7. 
Install the new relay, p/n 233-47642-00. 
Step 8. 
Re-connect the wires removed in Step 5 to their proper locations. 
Step 9. 
Re-install the Setback Control Junction Box Assembly cover and the (2) 
screws removed in Step 3. 
Relay Replacement 
White Wire 
Yellow Wire
Red Wire 
Blue Wire 
Setback Control Junction 
Box Assembly Cover 
Relay 
Relay 
Socket 
Screw (other not 
shown)
29