required by these appliances, you might create the potential for scald injury.  To protect against injury, you must install the ASSE 
approved mixing valve supplied with the water heater in the water system.  This valve will reduce point of discharge temperature by 
mixing cold and hot water in branch supply lines.  Follow the instructions supplied with the mixing valve for proper installation and 
adjustment.  The following chart details the relationship of water temperature and time with regard to scald injury and may be used 
as a guide in determining the safest water temperature for your applications. 
 
Approximate Time/Temperature Scald Chart 
 
APPROXIMATE TIME/TEMPERATURE 
RELATIONSHIPS IN SCALDS 
120°F (49°C) 
More than 5 minutes 
125°F (52°C) 
1½ to 2 minutes 
130°F (54°C) About 
30 
seconds 
135°F (57°C) About 
10 
seconds 
140°F (60°C) 
Less than 5 seconds 
145°F (63°C) 
Less than 3 seconds 
150°F (66°C) 
About 1½ seconds 
155°F (68°C) 
About 1 second 
Table 2. 
ALTERNATE SPACE HEATING WATER CONNECTIONS 
 
 
DANGER
 
Toxic chemicals, such as those used for boiler treatment, must not be introduced into potable water used for space heating. 
This water heater must not be connected to an existing heating system or component(s) previously used with a non-potable 
water heating appliance. 
All piping components connected to this water heater for space heating applications must be suitable for use with potable 
water. 
 
 
WARNING
 
When the system requires water for space heating at temperatures higher than required for other means, the supplied ASSE 
approved mixing valve must be installed to temper the water for those uses in order to reduce the scald hazard potential. 
Failure to properly pipe this water heater may result in improper operation and damage to the water heater or structure. 
Oxygen contamination of this water heater will cause corrosion of iron and steel components, and can lead to water heater 
failure.   
 
Connect the system supply and return piping to the water heater.   
 
Refer to Figure 10 and Figure 11 for installation examples.  Maintain 
a minimum ½ inch (1.3 cm) clearance from hot water piping to 
combustible materials. 
 
 
 
 
 