Copper Brute B4 Volume Water Heaters
Page 3
SECTION 1. 
General Information
1.1  Introduction
This manual provides installation, operating, and 
maintenance instructions for Copper Brute Volume 
Water Heaters, Sizes 175 through 400. Review all 
application and installation procedures completely 
before proceeding with the installation. Experience 
has shown that most operating problems are caused by 
improper installation. 
1.2  Warranty
The Copper Brute heaters are sold with a limited 
factory warranty. 
Make all warranty claims to an authorized 
Bradford White representative or directly to the 
factory. Claims must include the heater serial number 
and model (this information can be found on the rating 
plate), installation date, and name of the installer. 
Shipping costs are not included in the warranty 
coverage.
Some accessory items are shipped in separate 
packages. Inspect everything for damage immediately 
upon delivery, and advise the transporter of any 
shortages or damage. Any such claims should be filed 
with the transporter. The transporter will not accept a 
claim from the shipper, Bradford White.
The warranty does not cover damage caused by 
improper installation, operation, or field modification.
1.3  Technical Assistance
Consult Bradford White or your local wholesaler 
with any questions or problems involving the 
specification, installation and operation of Bradford 
White equipment. An experienced technical support 
staff is ready to assist in assuring the proper 
performance and application of Bradford White 
products.
                     Gas Connection                                                                                            
                               Size                           Water                                                                 C                     C                     V 
                                                               Connect.                                                        U.S. Only         (Indoor)              Vent
                   Nat.            Propane             Size                   A                     B              (Outdoor)                                    Dia.
Size     in.       mm       in.       mm       in.       mm       in.       cm        in.       cm       in.       cm       in.        cm       in.       mm
175       
3
/
4
        19        
1
/
2
        13       1
1
/
2
        38        18        46      26
1
/
2
      67     14
1
/
16
     36       23/
2
      60         6        152
250       
3
/
4
        19        
1
/
2
        13       1
1
/
2
        38      22
1
/
2
       57        31        79     18
1
/
16
     47       24
3
/
4
      63         7        178
325       
3
/
4
        19        
1
/
2
        13       1
1
/
2
        38      26
3
/
4
      68      35
3
/
4
       91     19
3
/
16
     49       25
7
/
8
      66         8        203
400       
3
/
4
        19        
1
/
2
        13       1
1
/
2
        38      31
3
/
4
       80      40
1
/
4
      102     22
5
/
8
      58       26
7
/
8
      68         9        229
Note: Dimensions may vary.
Figure 1. General configuration.
A
8-1/2 in.
(216mm)
INLET OUTLET
TOP VIEW
C
C
OPTIONAL
VENT CAP FOR
OUTDOOR USE
DRAFTHOOD
DRAFTHOOD MUST
BE INSTALLED IN
THE FIELD
HEADER
LOCATION
OUTLET
40-9/16 in. (1030mm)
INLET
5-1/2 in.
(140mm)
26-1/2 in.
(673mm)
SIDE VIEW
V
30-3/16 in. (767mm)
B
Dimensions shown in inches cm.