SECTION 1.
General Information
1.1  Introduction
This manual provides information for the 
installation and operation of Bradford White volume 
water heaters. It is strongly recommended that all 
application and installation procedures be reviewed 
completely before proceeding with the installation. 
Consult the Bradford White factory, or local factory 
representative, with any problems or questions 
regarding this equipment. Experience has shown that 
most problems are caused by improper installation.
Some accessory items are shipped in separate 
packages. Verify receipt of all packages listed on the 
package slip. Inspect everything for possible damage 
upon delivery, and inform the carrier of any shortages 
or impairments. Any such claims should be filed with 
the carrier. The carrier, not the shipper, is responsible 
for shortages and damage to the shipment whether 
visible or concealed. 
WARNING
All volume water heaters must be installed in 
accordance with the procedures outlined in 
this manual. The warranty does not apply to 
heaters not installed or operated in accordance 
with these procedures. Consult local building 
and safety codes before proceeding with 
work. The installation must conform to the 
requirements of the authority having jurisdiction 
or, in the absence of such requirements, to 
the latest edition of the National Fuel Gas 
Code; ANSI Z223.1, National Electrical Code 
ANSI/NFPA 70 and/or in Canada CSA B149.1 
requirement.
When required by the authority having 
jurisdiction, the installation must conform to 
the Standard for Controls and Safety Devices 
for Automatically Fired Boilers, ANSI/ASME      
CSD-1. Any modification to the water heater, 
its gas controls, gas orifices, wiring or 
draft diverter may void the warranty. If field 
conditions require such modifications, consult 
factory.
1.2  Heater Identification
Consult rating plate on the heater. The following 
example simplifies the heater identification.
            1            2          3         4        5          6
           B4        1670       I         N       09        C
1.      Basic heater model.
2.      Input rate X 1000 BTU/hr.
3.      Indoor (I) or Outdoor (E) installation.
4.      Gas type: Natural (N) or Propane (P).
5.      Ignition system: I.I.D. (09) or continuous pilot 
(16).
6.      Firing rate: On/Off (C), 2-stage (K), 4-stage (L).
Bradford White commercial water heaters are 
available in two models: an indoor version and an 
outdoor version. Both are available from the factory 
(see Figure 1).
1.3  Flow Requirements
For proper operation, all low volume hot water 
heaters must have continuous flow through the heat 
exchanger when firing. The system pump must be 
capable of developing sufficient pressure to overcome 
the resistance of the heater plus the entire circulating 
system at the designed flow rate.
Figure 1. Heater Configuration.
Pump
121⁄4
(311)
Gas
Conn.
A
Front
Top
V
101⁄4
(260)
29
5
/
8
(752)
C
17
(432)
281⁄4
(718)
Side
173⁄4
(197)
Rear
Out     In
29
(737)
B
Pump
19
(483) Gas
Inlet
12
(305)
A
Front
303⁄4
(781)
61
(1549)
Out      In
14
(356)
73⁄4
(197)
413⁄4
(1060)
Side
4
(102)
58
(1473)