Bradford-White Corp 238-44422-00G Manual De Usuario

Descargar
Página de 20
 
15
Thermostat Adjustment 
 
 
The temperature of the water can be changed by adjusting the thermostat(s).  
Before any work is done on the water heater, disconnect all power to the 
water heater by opening the switch at the main electrical circuit breaker or 
fuse box.  Remove the access panels or front panel on table tops, fold the 
insulation outward away from the controls.  Set the thermostat(s) to the 
desired water temperature using a screwdriver to move the thermostat dial.  
The thermostat has been factory preset to approximately 120°F (49°C).  
Rotate the temperature dial clockwise to increase water temperature.  
Replace the insulation making sure that the controls are well covered and 
that the plastic terminal shield has not been displaced; replace the access 
panel.  The water heater is now ready for operation and the main switch can 
be closed. 
 
 
 
Figure 4 
CAUTION
 
Before adjusting thermostat(s), turn off power supply to the water heater. 
 
 
Hotter water increases the risk of scald injury.  Scalding may occur within 
five (5) seconds at a temperature setting of 140°F (60°C).  To protect 
against hot water injury, install an ASSE approved mixing valve in the water 
system.  This valve will reduce point of discharge water temperatures by 
mixing cold and hot water in branch water lines.  A licensed plumbing 
professional or local plumbing authority should be consulted. 
 
Note: This water heater is equipped with an energy cut out device to 
prevent overheating.  Should overheating occur, turn off the electrical 
supply to the water heater and contact a qualified service technician. 
DANGER