D9412GV2/D7412GV2 | Operation and Installation Guide | 10.0  
Off-Board Relays 
 
Bosch Security Systems, Inc. | 5/05 | F01U003641B 
49 
 
 
Figure 21:  D8129 Connections to the D7412GV2 
Pin
Battery
amming
E CONNECTIONS
POWER +
DATA BUS A
DATA BUS B
COMMON
ZONEX OUT 1
ZONEX IN 1
32
31
30
29
28
27
NOT USED
26
25
NOT USED
EX POWER +
24
X COMMON
23
D5200/D5360
PROG CONN
2
3
3
1
2
3
4
5
6
7    8
1
DATA
AUX
GND
 
1 -  D8129 OctoRelays for relay numbers 1 to 64. 
Connect OctoRelays in parallel. 
2 -  Power limited 
3 -  Supervised, power limited 
 
10.1.1  Configuring the D8129 OctoRelay 
Five switches on the OctoRelay determine the relay 
numbers for the eight relay outputs (
Error! Reference 
source not found.
). 
Table 18: 
D8129 OctoRelay Switch Settings 
 
Panel Relay 
Number 
D8129 OctoRelay 
Switch Setting 
On Panel, Connect 
D8129 to: 
1 to 8 
Off-On-On-On-On 
Zonex 1 Terminal 28 
9 to 16 
On-Off-On-On-On 
Zonex 1 Terminal 28 
17 to 24 
Off-Off-On-On-On 
Zonex 1 Terminal 28 
25 to 32 
On-On-Off-On-On 
Zonex 1 Terminal 28 
33 to 40 
Off-On-Off-On-On 
Zonex 1 Terminal 28 
41 to 48 
On-Off-Off-On-On 
Zonex 1 Terminal 28 
49 to 56 
Off-Off-Off-On-On 
Zonex 1 Terminal 28 
57 to 64 
On-On-On-Off-On 
Zonex 1 Terminal 28 
D7412G Maximum 
65 to 72 
Off-On-On-On-On 
Zonex 2 Terminal 26 
73 to 80 
On-Off-On-On-On 
Zonex 2 Terminal 26 
81 to 88 
Off-Off-On-On-On 
Zonex 2 Terminal 26 
89 to 96 
On-On-Off-On-On 
Zonex 2 Terminal 26 
97 to 104 
Off-On-Off-On-On 
Zonex 2 Terminal 26 
105 to 112 
On-Off-Off-On-On 
Zonex 2 Terminal 26 
113 to 120 
Off-Off-Off-On-On 
Zonex 2 Terminal 26 
121 to 128 
On-On-On-Off-On 
Zonex 2 Terminal 26 
 
 
10.1.2 Relay 
Outputs 
 
 
Relay outputs can activate when you are 
setting the OctoRelay switches or 
programming the control panel.  
Disconnect equipment connected to relay 
outputs when you perform these functions. 
Each OctoRelay output provides a Form C dry contact 
rated for 1.0 A at 12 VDC. Normally-open, common, 
and normally-closed terminals are available for each 
relay output. When an individual output is activated, 
there is continuity between the normally-open and 
common terminals. When the output is not activated, 
there is continuity between the normally-closed and 
common terminals.  
10.1.3 Installation 
Set the switches on the OctoRelay before installing it in 
the enclosure. Refer to Section 10.1.1 Configuring the 
D8129 OctoRelay
 on this page. 
Install the OctoRelay in the enclosure with the control 
panel (Figure 2 on page 9) or in an adjacent enclosure 
that is no more than 1.5 m (5 ft.) from the control 
panel. Use 1.5 mm (16 AWG) to 0.8 mm (22 AWG) 
wire.