5.2  Maximum Bandwidth HDMCII VDSL2 LAN Extender Module 
(Extended Temp) Link LEDs 
The standard single pair HDMCII VDSL2 LAN Extender Module (Extended 
Temp) unit will provide the following Rate/Reach performance under the best 
conditions and still maintain a BER > 10^-9 performance over single pair 24 
AWG (0.5mm) twisted wire. 
HDMCII VDSL2 LAN Extender Module (Extended Temp) Rate/Reach 
Distance   Link  Link  Link
Link 
BW 997 
BW 998 
(feet) 
<Mbps 
(down)
<Mbps 
(up) 
<Mbps 
(down) 
<Mbps 
(up) 
<950 1 1 1 1  93  76  99  50 
950 1 
1 1 74 64  90  45 
1200 1 1 0 1  64  56  81  39 
1500 1 0 1 1  52  47  70  30 
1800 1 0 0 1  43  35  59  22 
2300 0 1 1 1  33  20  45  12 
3200 0 1 0 1  24  9  29  5 
4700 0 0 1 1  17  1  18  1 
5500 0 0 0 1  11  1  11  1 
>5500 
no Link
no Link 
no Link 
no Link
The unit will automatically adjust to reach the best bandwidth performance 
for the physical line it is connected to.  The associated LED display will 
indicate the Bandwidth performance the unit is running at any given time.  
This is not the bandwidth that is being transmitted but the bandwidth 
capability of the line.
  The Bandwidth number is based on "VDSL User 
Payload" and includes the VDSL Frame overhead.  For Band Plan 998, this 
LED display will indicate the MAX down stream rate to the Remote unit. 
Band Plan 997 will provide the greatest symmetrical bandwidth the line can 
support.  The end user can also select Band Plan 998 for asymmetric 
operation, to provide better downstream performance.  Either plan will 
automatically adjust for the greatest bandwidth transport.  The HDMCII 
VDSL2 LAN Extender Module will automatically seek the best operating 
condition for the physical line it is connected to. 
 
NOTE
 
The RANGE is only an approximation based on a typical line in a normal noise 
environment.  Actual distances will vary depending on the condition of the physical 
line in use.