4. Description of LED Functions
Table 1. LEDs and their functions.
  LED 
State 
Function 
Description
  ON, CONNECT,  
All three LEDS light 
Power up 
Upon power-up, all three LEDs will light for two seconds, as  
  FAULT LEDs 
 
 
part of the self-test for the internal microprocessor software. 
  ON LED 
Lights green after  
DC output  
After two seconds, the ON LED will light green, indicating that 
   
two seconds 
voltage available 
the DC output voltage is available for powering an 802.3af  
   
 
 
PoE compliant load.
  CONNECT 
Lights green 
802.3af load 
This green LED lights when a compliant load is attached to  
 
  LED 
 
is attached 
the output RJ-45 connector.
   
Blinking 
802.3af load  
If the load does not comply with 802.3af PoE standards,  
   
 
is not attached 
 then the LEDs will blink a code indicating that the load was not 
detected. See Table 2 for code descriptions.
  FAULT LED 
Lights red 
Overload or  
If a fault, such as an overload or short circuit, occurs, then the 
   
 
short circuit 
red FAULT LED lights. See Table 2 for code descriptions.
   
Lights red for  
Power supply is 
The red LED will light for two seconds and then go off as the  
   
two seconds, 
trying to re-detect 
power supply tries to re-detect a valid load. If a compliant  
   
then goes off 
a valid load 
 802.3af PoE load is NOT detected, the LED will indicate the problem 
as described in Table 2.
Table 2. Failure detection codes.
  Code   
Name   
 
 
 
 
Description
  1 
 
Incorrect resistive signature   
 
 
The green CONNECT and red FAULT LEDs blink three times.
  2 
 
Incorrect capacitive signature 
 
 
The green ON LED blinks three times.
  3 
 
Incorrect V offset   
 
 
 
The green CONNECT and green ON LEDs blink three times.
  4 
 
Unstable current measurement 
 
 
The green ON LED blinks three times.
  5 
 
Low voltage sensed during detection (overload)  
The red FAULT LED blinks three times.
NOTE:  After the LEDs blink three times, the power injector will continue to try to detect a valid load. Until the correct load is applied, the LEDs  
will continue to blink. If an open circuit is connected to the output RJ-45 connector, then the LEDs will not blink but the power injector will 
continue to try to detect a valid load. 
 
FREE, live, 24/7 Tech Support is just 20 seconds away. 
724-746-5500   |   blackbox.com
Black Box and the Double Diamond logo are registered trademarks of BB Technologies, Inc.  
  Bluetooth is a registered trademark of The Bluetooth SIG, Inc.Any other trademarks    
  mentioned in this manual are acknowleged to be the property of the trademark owners.
BLACK BOX
®
©
 Copyright 2011. All rights reserved.
Figure 3. Cable connections to the power injector.
LPJ001A-F, version 2