9. Your BIONAIRE
®
Console Humidifier is now ready for use again.
NOTE: The float must be properly installed in the base for the
refill light to illuminate when water level is low.
STORAGE TIPS
If you do not plan to use your unit for an extended period of time
(i.e., during the summer months), it is important that you follow
these instructions to help prevent stagnation of water in the unit.
1. Clean your humidifier as instructed in the section titled 
"Cleaning and Maintenance."
2. Make sure all water is emptied from the water reservoir 
and water tray.  Discard the wick filters (if they need to 
be replaced).  For optimum performance, the wicks 
should be replaced a minimum of once per season 
or more often if the unit is used in hard water conditions.
3. Dry your unit thoroughly.
4. Leave the reservoir caps off the reservoirs, allowing 
them to be exposed to air.
5. Pack your humidifier in its original carton and store 
in a cool, dry place.
6. Order your replacement Wick Filter (Model 900) 
and Air Filter (Model 911D) by calling 1-800-253-2764 
in North America, or through www.bionaire.com.
Trouble
Probable Cause
Solution
Unit not operating;
☛ Power cord is not 
✔ Connect the power 
Power light is not
properly connected 
cord onto the unit and 
illuminated 
to the unit and the 
into the power source.
power source.
☛ Power failure.
✔ Check circuit breaker 
or outlet.
Empty/"Refill" light 
☛ Water reservoirs need ✔ Remove water 
is on.
refilling.
reservoirs and refill.
☛ Float is not correctly 
✔ Carefully reposition
positioned.
float in the unit.
☛ Unit is not level.
✔ Place unit on a 
level surface.
☛ Scale buildup on tray. ✔ Clean according 
to cleaning instructions.
Mist output minimal 
☛ Wick filters have not
✔ Wait 30 minutes 
to none.
absorbed water.
before starting 
humidifier.
☛ Mineral buildup
✔ Remove tray, clean
in tray.
according to cleaning 
instructions.
☛ Digital Humidistat is 
✔ Set Humidistat higher
set too low.
if desired.
Troubleshooting for your Console Humidifier
Trouble
Probable Cause
Solution
Mist output minimal
☛ Filter needs to be 
✔ Replace wick filter by
to none (cont’d.).
replaced.
visiting our website at
www.bionaire.com or
calling 1-800-788-5350.
☛ Normal 
✔ Mist is invisible.
Unit is continuously
☛ The Digital humidistat
✔ Reset the humidistat
operating while on
is set at a higher level
to a lower setting if
the AUTO setting.
than the present level
desired.
of humidity in the room.
Wick filter turns 
☛ Wick filter needs to be ✔ Replace the wick filter by
replaced.
visiting our website at
www.bionaire.com or
calling 1-800-788-5350.
WARRANTY
Bionaire
®
warrants to the first retail purchaser, for TWO (2)
YEARS from the date of original purchase, either to repair or
replace at its option, without charge (parts and labor),any 
supplied or manufactured part of this humidifier which, upon
inspection by an authorized service center, proves to have failed
in normal use due to defects in material or workmanship, or, at
its option, to replace the unit. Operation under conditions other
than those recommended or at voltages other than the voltage
indicated on the unit, or any attempts by unauthorized 
personnel to service the unit or modify it, will render the 
guarantee void. Bionaire
®
shall not be liable for any personal
injury, property damage or any incidental or consequential 
damages of any kind (including water damage), resulting from
defects, malfunctions, misuse, improper installation or alteration 
of the product.
BIONAIRE
®
EXPRESSLY DISCLAIMS ALL RESPONSIBILI-
TY FOR CONSEQUENTIAL DAMAGES OR INCIDENTAL
LOSSES CAUSED BY USE OF THIS PRODUCT. 
The provisions of this warranty are in addition to, and not a
modification of, or subtraction from the statutory warranties 
and other rights and remedies contained in any applicable 
legislation and to the extent that any such provision purports 
to disclaim, exclude or limit any such statutory warranties or
other rights or remedies, such provisions shall be deemed 
to be amended to the extent necessary to comply therewith.
For Warranty Service, please call 1-800-788-5350 
in North America.
A Bionaire
®
consumer service representative will help 
determine which is the best procedure in order for your 
humidifier to be repaired.
KEEP THIS NUMBER FOR FUTURE REFERENCE.
Troubleshooting for your Console Humidifier (Cont’d)