Bil-Jax Personal Lift AERIAL WORK PLATFORMS Hydraulic Boom Lift Manual De Usuario

Descargar
Página de 136
XLB-4319 
 
4-20 
 
4-7 TROUBLESHOOTING 
Table 4-3.   Troubleshooting Chart 
Problem Cause 
Correction 
a.  Emergency stop engaged (pushed in).
 
b.  Battery charge is low. 
 
c.  Battery ground or in-series cable 
loose. 
d.  Main circuit breaker tripped or 
switched off. 
a.  Rotate emergency stop buttons clock-
wise to disengage. 
b.  Check charge level. Recharge battery 
if needed. 
c.  Check for and repair loose battery 
connections or ground fault. 
d.  Reset main circuit breaker inside 
ground control panel. 
a.  Main disconnect unplugged. 
b.  Fuse F2 burned out. Fuse is mounted 
on front inner wall of boom pivot 
weldment, in series with the positive 
battery cable. 
c.  Motor contactor failed. 
d.  Pump motor failed. 
a.  Plug in main disconnect. 
b.  Correct cause of short circuit and 
replace fuse. 
 
 
c.  Replace motor contactor. 
d.  Check pump motor operation; repair 
or replace motor if faulty. 
1.  Engine or motor will not 
start. 
 
 
 
 
 
DC model only 
 
 
 
 
 
 
Gas model only
a.  Engine key switch in wrong position. 
b.  Fuel tank empty. 
c.  Engine oil level low. 
d.  Spark plug fouled or damaged. 
e.  Fuse F2 burned out. Fuse is mounted 
inside engine key switch housing. 
f. 
Starter relay or starter motor failed. 
a.  Turn key switch to run position. 
b.  Refill fuel tank. 
c.  Check/add engine oil. 
d.  Check/replace spark plug. 
e.  Correct cause of short circuit and 
replace fuse. 
f. 
Replace failed starter relay or motor. 
a.  Basket/ground key switch in wrong 
position. 
b.  Hydraulic oil level low. 
 
c.  Boom down limit switch or switch 
wiring failed. 
d.  Hydraulic gear pump failed. 
a.  Turn key switch to ground position. 
 
b.  Check hydraulic oil level in reservoir. 
Add oil as needed. 
c.  Check boom down limit switch and 
d.  Check pump; replace if hot to touch. 
a.  Boom enable valve SV1 faulty (stick-
ing open) (see item 4, Figure 6-19). 
a.  Repair or replace faulty valve. 
2.  Pump motor runs, but out-
riggers will not extend. 
 
 
 
 
DC model only 
 
Gas model only
a.  Outrigger enable valve solenoid SV2 
failed (see item 6, Figure 6-18). 
b.  Boom enable valve SV1 faulty (stick-
ing open) (see item 1, Figure 6-18). 
a.  Replace faulty wiring or solenoid. 
 
b.  Repair or replace faulty valve.