In each case pressing on the opposite key while holding the key being used will accelerate
the operation being carried out.
Fig. 1.2:  The rear panel layout of the ULTRA-CURVE PRO
9
This is the MAINS CONNECTOR/FUSE HOLDER/VOLTAGE SELECTOR. Before you connect the
unit, please make sure that the displayed voltage corresponds to your mains supply. Please note that,
depending on the mains voltage supplied to the unit, the correct fuse type and rate must be installed. In
some units, the fuse holder can be inserted in two positions to switch between 220 to 240 V and 100 to
120 V. Please note that a higher fuse rating must be used when operating the unit outside of Europe
with 115 V (see chapter 6 “INSTALLATION”).
10
Please use the enclosed mains cable to connect the unit to the mains power supply.
11
The MAINS SWITCH is to be found above the mains socket. The switch is situated on the rear panel to
make the ULTRA-CURVE PRO tamper proof with unattended use. The unit will bypass on power failure
but cannot be bypassed when a password is set.
12
SERIAL NUMBER. Please take the time to have the warranty card filled out completely by your specialized
dealer, and return it within 14 days after the date of purchase, so as to be entitled to benefit from our
extended warranty. You may also use our online registration option available on the Internet at
www.behringer.com.
13
AES/EBU IN and AES/EBU OUT. These are the ULTRA-CURVE PRO’s digital input and output (optional).
The analog output signal is also present at the (analog) outputs when the digital out is used. Both
signals can be used in parallel.
14
These are the ULTRA-CURVE PRO’s MIDI connectors (MIDI IN/OUT/THRU). Via these connectors
total remote control is possible.
15
ANALOG OUTPUTS. These are the ULTRA-CURVE PRO’s analog outputs. When the AES/EBU option
is installed the analog output will still be present at these outputs, so that both analog and digital out can
be used in parallel.
16
These are the ULTRA-CURVE PRO’s ANALOG INPUTS.
17
This is the MIC INPUT socket for the reference microphone.
2. OPERATION
The BEHRINGER ULTRA-CURVE PRO is a flexible, universally applicable sound processing and measurement
device, whose operations may be divided into two basic areas; signal processor (equalizer, limiter) or real Time
analyzer (RTA). For this reason, you always operate in either EQ or RTA mode. Simultaneous operation of
both is not possible!
Upon switching on the ULTRA-CURVE PRO you will be presented either the main equalizer (EQ), or analyzer
(RTA) window. By pressing the EQ or RTA key, the ULTRA-CURVE PRO will switch from RTA- into EQ mode
and vice versa. When the ULTRA-CURVE PRO is switched from one mode to the other, the outputs will be
briefly muted.