Reference Guide for the Model RM356 Modem Router
Troubleshooting
10-5
 
2.
Verify that the IP address is supplied correctly in Menu 13 if the remote dial-in user is 
negotiating IP. 
Check that the remote dial-in user is supplying a valid IP address and that the router is 
assigning a valid address from the IP pool.
3.
Verify the user name and password for the remote dial-in user in Menu 14. 
If you are still unable to determine the problem, refer to “
” on 
.
Troubleshooting the Manager Interface
Refer to the following instructions if you cannot access the Manager interface by the serial port 
or by using the Telnet Protocol.
If you cannot access the Manager interface by the serial port:
1.
Verify that the router is connected to the serial port of your terminal or computer using 
the included cable.
2.
Check the configuration parameters of your terminal or communications program. 
The connection should be configured as follows:
VT100 terminal emulation
9600 baud rate (unless this setting has been changed previously in the router setup)
No parity, 8 data bits, 1 stop bit
No flow control
If you cannot access the Manager by using the Telnet Protocol, refer to 