Using the Console Interface
893-00992-B
3-15
 
*. The Trap IP Address and Community String fields can be set using a MIB table (in a Bay Networks proprietary MIB). The 
status of the row in the MIB table can be set to Ignore. If the row status is set to Ignore, the fields appear to be set when 
viewed from the console terminal; however, no traps will be sent to that address until the row status is set to Valid.
Table 3-3.
SNMP Configuration screen fields 
Field
Description
Read-Only 
Community String
The community string used for in-band read-only SNMP operations.
Default Value
public
Range
Any ASCII string of up to 32 printable characters
Read-Write 
Community String
The community string used for in-band read-write SNMP operations.
Default Value
private
Range
Any ASCII string of up to 32 printable characters
Trap #1 IP Address*
Number one of four trap IP addresses. Successive trap IP address fields are 
numbered 2, 3, and 4. Each trap address has an associated community 
string (see the next field description).
Default Value
0.0.0.0 (no IP address assigned)
Range
Four-octet decimal IP address notation, where each 
octet of the address is represented as a decimal value, 
separated by a decimal point
Community String
The community string associated with one of the four trap IP addresses 
(see the Trap #1 IP Address field description).
Default Value
Zero-length string
Range
Any ASCII string of up to 32 printable characters
Authentication Trap
Determines whether a trap will be sent when there is an SNMP 
authentication failure.
Default Value
Enabled
Range
Enabled, Disabled