Baumatic BCG520BL Manual De Usuario

Descargar
Página de 44
o
 
Unscrew the injector and replace it with the required injector for 
the new gas supply according to the table below.  
 
Burner Type 
Gas Type  Pressure 
Mbar 
Injector 
Marking 
(1/100mm) 
Power 
(Kw) 
Max Min 
Natural 
Gas 
20 1.05 
Oven Burner 
Liquid Gas  28..30/37 
0.72 
2.1 0.8 
 
Natural 
Gas 
20 1.00 
Grill Burner 
Liquid Gas  28..30/37 
0.66 
1.8 0.6 
 
o
 
After changing the injectors YOU MUST change the minimum 
flow rate.  
 
Minimum flow adjustment for the oven and grill burners 
 
 
All work must be carried out by a GASSAFE 
registered engineer. 
 
 
o
 
In order to access the adjusting screws to change the minimum 
flow rate of the grill and oven burners, you need to remove the 
hob top and control panel.  
 
o
 
To take the hob top off, remove the screws fixing the hob to the 
cooker.  
 
 
 
35
 
 
 
 
 
 
 
 
 
 
 
o
 
When all the screws have been removed, slide the hob from the 
back to the front and lift it off the support brackets which hold 
the hob down at the front of the cooker.