Bakers Pride 100 Manual De Usuario

Descargar
Página de 12
 
For European Community Countries: 
Designated European Market = 
Ö 
EN 437 
Gas Cat. 
Gases and Supply 
Pressures 
A
T
B
E
D
K
F
F
R
G
R
D
E
I
I
L
N
P
T
E
S
S
E
G
B
I
2H
 
G20 @ 20mbar 
Ö   Ö Ö       Ö  Ö      Ö Ö Ö Ö
I
2L
 
G25 @ 25mbar 
 
 
 
 
 
 
 
 
 
 
Ö         
I
2E
 
G20 
20mbar 
      
Ö     Ö           
I
2E+
 
G20/25 @ 20/25mbar 
 
Ö     Ö                    
 
For North America: 
Type of Gas   
Manifold Pressure 
            Natural  
         3.5” Water Column 
            LP 
 
          10” Water Column 
 
MODELS COVERED 
     MODEL 
 
               BTU/hr 
 
 
     kw 
100 
Series 
  48,000 
   14.06 
200 
Series 
  60,000 
   17.53 
300 
Series 
  70,000 
   20.50 
400 
Series 
  80,000 
   23.44 
3151 
Series 
  70,000 
   20.50 
4151 
Series 
  70,000 
   20.50 
D-125   
 
         *125,000  
 
           *36.61 
DS-805   70,000 
   20.50 
GS-805   60,000 
   17.58 
Y-600   
 
          120,000  
 
 
35.15 
Y-800   
 
          120,000  
 
 
35.15 
*Model D-125 is rated 105,000 BTS/hr (30.76 kw) for use with LP Gas. All other models have the same 
rating for Natural and LP Gas. LP Gas models are not available for European Community Countries. 
 
 
I. INSTALLATION INSTRUCTIONS 
1.RECEIVING:   
Read the notice on the outside carton regarding damage in transit. Damage discovered after opening 
the crate(s)/carton(s) is ‘CONCEALED DAMAGE’ and the carrier must be notified immediately to send 
an inspector and also to furnish forms for the consignee’s claim. 
 
When the oven arrives, it should consist of: 
a) A crate or carton containing your new oven. 
b) A carton containing 4 legs with mounting hardware. 
c) A strapped skid containing baking decks. 
 
Installation must conform with local codes and/or with the latest edition of the ANS Z-223.1 
National Fuel Gas Code in USA ( CAN/CGA-B 149.1 or 2 Installation Code in Canada). 
This appliance must be installed by a competent person in accordance with the rules in force. In 
the U.K. Corgi registered installers (including the regions of British Gas) undertake to work to 
safe and satisfactory standards. This appliance must be installed in accordance with the current 
Gas Safety (Installation and Use) Regulations and the relevant Building Regulations / IEE 
Regulations. Detailed recommendations are contained in the British Standard Codes Of Practice 
BS 6172, BS 5440:Part 2 and BS 6891.   
Place the oven and parts as close as possible to the area of final installation before uncrating. 
 
 
 
 
3