Burnham Series 8H/8HE Boiler Folleto

Descargar
Página de 4
*Ratings shown are for installations at sea level and elevations up to 2,000 feet. For elevations above 2,000 feet, ratings should be reduced at the rate of four percent (4%) for each 1,000 feet above sea level.
1. When ordering, use prefix P for packaged and K for knocked-down.  Use suffix NSP for natural gas, standing pilot; NEI for natural gas, electronic ignition; PSP for LP gas, standing pilot; PEI for LP gas, electronic ignition.
2.  Net I=B=R ratings shown are based on normal I=B=R piping and pickup allowance of 1.15. Consult the Burnham Commercial website for installations having unusual piping and pickup requirements such as intermittent  
system of operation, extensive piping systems, etc.
3. 15 foot height is measured from top of drafthood to top of chimney.
4. 805H Efficiency is AFUE.
Maximum allowable working pressure: 50 PSI Water only; 50 PSI Safety Relief Valve - Standard; 30 PSI Safety Relief Valve - Optional 
Packaged units are shipped packaged and wired in a reinforced cardboard container, for added protection. Drafthood, trim carton, low water cut-off and damper; when supplied, are shipped in separate cartons. Knocked-down  
units are shipped in a stackable container with sections assembled and mounted on the base with manifold and burners installed. Controls, trim, drafthood, and jacket are shipped together in the same container as the boiler. 
NOTE: NOT FOR DIRECT INSTALLATION ON COMBUSTIBLE FLOORING. A HEAT SHIELD IS REQUIRED AND AVAILABLE FOR COMBUSTIBLE FLOOR INSTALLATION AND CONCRETE INSTALLATION WHICH IS OVER A MATERIAL  
THAT IS SUBJECT TO MELTING (PVC, PEX RADIANT TUBING ETC.). NOT FOR INSTALLATIONS ON CARPET, EVEN WITH A COMBUSTIBLE FLOOR SHIELD.
All dimensions are in inches
Form No. PL81401161000-1/14-2.5Ms   Printed in the U.S.A.
Dimensions and Specifications
©2014 Burnham Commercial  
  P.O. Box 3939, Lancaster, PA 17604
Phone: 888.791.3790  
  www.burnhamcommercial.com
4
PA
G
E
Series 8H/8HE Ratings* Natural and LP Gas
Boiler  
Model (1)
Input  
(MBH)
Gross Output 
(MBH)
I=B=R Net 
Rating Water 
(MBH) (2)
Thermal 
Efficiency(4)
24V
EI
Recommended 
Chimney Size 
(Round)
Water  
Content  
(Gallons) Packaged Knock-down
805H
806H
807HE
808HE
809HE
810HE
252
315
340
410
460
505
208
253
275
328
370
406
181
220
239
285
322
353
82.7
80.2
81.0
80.1
80.4
80.5
N/A
4.5
5.0
N/A
N/A
N/A
4.5
4.5
4.5
4.5
5.0
5.0
7" dia. x 15ft.
8" dia. x 15ft.
8" dia. x 15ft.
8" dia. x 15ft.
10" dia. x 15ft.
10" dia. x 15ft.
11.9
13.9
15.9
17.9
19.9
21.9
600
690
770
880
970
1060
680
770
870
950
1040
1140
RATINGS
MINIMUM NATURAL GAS  
PRESSURE (INCHES)
APPROX. SHIPPING 
WEIGHT (LBS.)
Boiler Model
‘A’
‘B’
‘C’
‘D’
‘E’
805H
806H
807HE
808HE
809HE
810HE
20
23-3/4
27-1/2
31-1/4
35
38-3/4
10
11-7/8
13-3/4
15-5/8
17-1/2
19-3/8
7
8
8
9
10
10
24-13/16
27-13/16
27-13/16
30-13/16
33-1/2
33-1/2
16-1/8
18
18
20
22
22
DIMENSIONS (INCHES)
Standard Equipment
Cast Iron Section Assembly 
 
Deluxe Jacket with 3 inch Insulation 
100% Shut-Off Gas Controls
Boiler Drain Valve 
 
50VA Transformer and Junction Box
Optional Equipment
 
Electronic Control Sets to Meet CSD-1
 
Deduct 751P-MT-120 low water cut-off (on 808HE thru 810HE)
 
Combustible floor shield (Required fir installation on combustible flooring)
Aluminized Steel Burners 
1" Gas Connection 
2" Supply and Return Connections
50 PSI Safety Relief Valve
Stainless Steel Flue Baffles 
Blocked Vent Switch (BVS) - All Sizes
Flame Roll-Out Switch (FRS) - All Sizes
L4080D High Limit Control
High Limit Control with Manual Reset -  
  L4006E (in addition to L4080) - Packaged Boilers Only 
751P-MT-120 Probe LWCO - 808HE-810HE Only
Electronic Ignition on 805H & 808HE - 810HE for Natural or LP Gas
24V Standing Pilot on 806H & 807HE for Natural or LP Gas
Pressure Temperature Gauge
Intermittent circulation—24V-R8285D relay in lieu of AT150D1001 (80160155)
30 psi relief valve in lieu of standard 50 psi relief valve (specify on order)
Vent damper (Optional on 806H + 807HE - 810HE, not available with “EP” or “OP” control sets)—(Standard on 805H)