Burnham Series 8H/8HE Boiler Manual De Propietario

Descargar
Página de 72
24
MINIMUM  INsTALLATION  cLEARANcEs  AROUND  MODULEs
fIGURE 2-10
TOTAL  fREE  AREA  Of  VENTILATION  OPENINGs,  sQ.  IN.
fIGURE 2-11
Drafthood & 
Vent connector
Top of 
Jacket
front
side
Rear
5  6 side-
by-side
6 back-to-
back
6 front-to-
front
805-806-807
To Combustible 
Construction
1  6"
2  36"
1  18"
1  6"
1  6"
N/A
N/A
N/A
Recommended 
For Servicing
N/A
1  24"
1  24"
8  18"
24"
1  1"
26"
7  36"
808-809-810
To Combustible 
Construction
1  6"
2  51½"
1  18"
1  6"
1  6"
N/A
N/A
N/A
Recommended 
For Servicing
N/A
7  24"
7  24"
8  18"
24" 
1  1"
26"
7  36"
N/A:  Not Applicable, 1 USA & Canada, 2 USA Only:  18" in Canada, 5 or as necessitated by prefabricated water manifolds, 6 
Consult Local Codes for minimum spacing of multiple boilers, 7 USA Only; 48" in Canada, 8 USA Only; 24" in Canada.
Unconfined Space with
Outdoor Vent
Confined Space with
Outdoor Vent
Confined Space
w/Inside Air
MBH Input 
5.0
MBH Input
4.0
MBH Input
1.0
MBH Input refers to total input for all appliances in the boiler room.