Burnham Series 5B Boiler Folleto

Descargar
Página de 4
Series 5B 
SPECIFICATIONS
4
PA
G
E
Series 5B Ratings
Boiler  
Model (1) Input
Gross  
Output
Steam
USA
Boiler
H.P.
(No.) & Size of  
Flue Outlets
Breeching
Diameter (In.)
Round Dia. 
In. x Ft.
Rectangular  
In. x In. x Ft.
Approx. Shipping 
Weight (Lbs.)
I=B=R 
Sq. Ft.
I=B=R 
MBH
5006B
5007B
5008B
5009B
5010B
5011B
5012B
5013B
5014B
5015B
5016B
5017B
5018B
5019B
5020B
5021B
5022B
5024B
5026B
401
468
546
624
702
780
858
936
1,014
1,092
1,170
1,248
1,326
1,404
1,482
1,560
1,638
1,794
1,950
321
375
437
500
562
624
687
749
812
874
936
999
1,061
1,124
1,186
1,248
1,311
1,436
1,560
1,004
1,171
1,367
1,558
1,754
1,950
2,146
2,342
2,538
2,729
2,925
3,121
3,317
3,513
3,704
3,900
4,113
4,546
4,975
241
281
328
374
421
468
515
562
609
655
702
749
796
843
889
936
987
1,091
1,194
9.58
11.04
12.88
14.73
16.57
18.41
20.25
22.09
23.93
25.77
27.61
29.45
31.29
33.13
34.97
36.82
38.66
42.34
46.02
(1) 9"
(1) 10"
(1) 12"
(1) 12"
(1) 12"
(2) 9"
(1) 9", (1) 10"
(2) 10"
(1) 10", (1) 12"
(2) 12"
(2) 12"
(2) 12"
(2) 12"
(2) 12"
(2) 9", (1) 12"
(1) 9", (1) 10", (1) 12"
(2) 10", (1) 12"
(1) 9", (3) 10"
(3) 10", (1) 12"
9
10
12
12
12
14
14
14
14
14
14
14
16
16
16
16
16
18
18
10 x 15
10 x 15
12 x 15
12 x 15
12 x 15
15 x 15
15 x 15
15 x 15
15 x 20
15 x 20
15 x 20
15 x 20
15 x 20
18 x 20
18 x 20
18 x 20
18 x 20
18 x 20
18 x 20
12 x 12 x 15
12 x 12 x 15
12 x 16 x 15
12 x 16 x 15
12 x 16 x 15
16 x 16 x 15
16 x 16 x 15
16 x 16 x 15
16 x 16 x 20
16 x 16 x 20
16 x 16 x 20
16 x 16 x 20
16 x 16 x 20
16 x 20 x 20
16 x 20 x 20
16 x 20 x 20
16 x 16 x 20
20 x 20 x 20
20 x 20 x 20
1,160
1,340
1,525
1,720
1,895
2,085
2,280
2,460
2,640
2,870
3,070
3,265
3,445
3,620
3,810
4,005
4,185
4,530
4,895
NET RATING (4) (5)
RATING MBH (2) (3)
RECOMMENDED  
CHIMNEY SIZE (6)
1.  Boiler Model Prefixes:  K - Knockdown;  A -  Assembled Sections.  Suffixes:  S - Steam.  N - Natural Gas;  P - LP Gas.  EI - Electronic Ignition;  
OP - Electronically Supervised Standing Pilot with Control Panel; EP - Electronically Supervised Electronic Ignition with Control Panel. (All 
Series 5B boiler models reach a combustion efficiency of 77%.)
2.  Ratings provided are for installations from sea level to 2000 ft. elevation. For altitudes above 2000 ft.: USA—Reduce ratings 4% for each 
1000 ft. above sea level. Canada—certified for use at altitudes to 4500 ft. above sea level. Each installation, however, must be authorized 
by local authorities.
3.  LP gas ratings reduced 6-1/4% from natural gas ratings.
4.  Net I=B=R ratings shown are based on normal I=B=R piping and pick-up factor. Steam:1.333 (5006B thru 5021B), 1.329 (5022B), 
1.317 (5024B), 1.307 (5026B).
5. Net ratings are U. S. A. only.
6.  Based on year-round use with 6 ft. breechings and no more than one elbow. Chimney height measured from installation floor line to 
chimney top. Flue size based on nominal size of unlined chimney. Flue lined with largest flue liner which will fit within these dimensions 
is constructed to have the same effective flue area. Individual vents—If boiler is equipped with individual vertical vent riser(s) of same 
size as flue outlet(s) on draft divert(s), these vent(s) should not be less than 5 ft. in height as measured from top of drafthood. For other 
chimney and breeching combinations, consult the manufacturer.
Note:  
Maximum Allowable Working Pressure (MAWP): 15 PSI Steam 
Gas Supply Pressure: Natural Gas - Maximum: 14" W.C.  
Minimum: 5.5" W.C. (5009B, 5011B thru 5014B and 5020B thru 5026B) 
Minimum: 5" W.C. (5006B thru 5008B, 5010B and 5015B thru 5019B) 
LP Gas - Maximum: 14" W.C. – Minimum: 11" W.C.
Not for installation on combustible flooring.