Cleaning the Paper Sensor, Waiting Sensors and Double Feed Detector
Preparation: Locate the blower accessory and remove the brush from the blower.
Press the power button to the OFF position.
Push the ADF door release button to open the ADF door.
Use the blower accessory to blow off any dirt from the surface of the paper sensor and waiting 
sensor. Also, blow off any dirt from the surface of the metal reflector sheet used by the waiting 
sensor.
Blower accessory
Blower
Sensor or detector
1
2
3
Waiting sensor
Reflector sheet for 
waiting sensor
Paper sensor