Bosch Appliances Video Game Controller D9412GV2 Manual De Usuario

Descargar
Página de 158
D9412GV2/D7412GV2 | Program Entry Guide | 2.0  GV2MAIN 
EN | 55 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
 
CC# Close Door 
CC# Passcode Follows Scope 
Default: 
No 
Default: 
Yes  
Selection: 
Yes or No 
Selection:  Yes or No 
Yes 
This keypad sounds a tone and 
displays CLOSE DOOR #. 
Yes 
Master Arming allows a user to 
change the armed state of the areas 
within the scope of this keypad. If the 
areas in the scope are already at the 
intended armed state, they remain in 
that state. 
No 
This keypad does not sound the 
tone or activate the display. 
Determines whether this keypad sounds an audible 
tone and displays the CLOSE DOOR # warning on 
the keypad. This occurs when the door is physically 
held open past the shunt time and the extend time 
has a value greater than zero for the door assigned to 
this area in CC# Assign Door. Refer to the D9210B 
Program Entry Guide
 (P/N: 32207). 
•  If the area to which this keypad is 
assigned is armed, entering a 
valid pass code disarms this area 
and all other areas assigned to 
the scope of this keypad.  
•  If the area to which this keypad is 
assigned is disarmed, entering a 
valid pass code arms this area 
and all other areas assigned to 
the scope of this keypad. 
 
CC# EnhancCmdCtr 
Default: 
No 
Selection: 
Yes or No 
No 
Restricts the scope of the keypad to 
the Area programmed in CC# Area 
Assign
 for the purpose of executing 
L## Passcode Arm and  
L## Passcode Disarm only. 
Yes 
This keypad is a D1260 Alpha V 
Keypad. 
No 
This keypad is not a D1260 Alpha V 
Keypad. 
Use this program to determine if this keypad follows 
CC# Scope or if it only arms or disarms the area to 
which it is assigned. The user must have authority 
enabled in L## Passcode Arm and L## Passcode 
Disarm
.This feature does not affect the Function List 
arming and disarming commands. 
When a D1260 Alpha V Keypad is installed at this 
keypad address, this item must be set to Yes.  
 
Reboot the system to enable an Alpha V 
keypad.  
To reboot the system, close and open the 
 
reset switch, labeled “S1 RESET,” 
located in the upper right corner of the 
control panel. 
 
Tokens and cards disarm according to 
this prompt. If this prompt is No, tokens 
disarm only the Area to which the CC# is 
 
assigned. The user must have disarming 
rights for tokens and cards programmed 
at the Disarm Level,. The user does not 
need disarming and arming authority for 
the keypad. 
 
You can use this prompt for a group of 
account-wide keypads that only arm the 
area to which they are assigned, even if 
 
the user has a pass code with arming 
authority rights in all areas.