Bosch Appliances Radio SC3100 Manual De Usuario

Descargar
Página de 32
 SC3100 
 
System Initialization  
 
SC3100 Operation and Installation Guide 
 
© 2004 Bosch Security Systems 
Page 21 
90026-201D 
5.0 System 
Initialization 
The following describes the System Initialization Procedures for the SC3100 Radio communicator. 
5.1 
System Initialization Procedures 
Contact the Central Station SAFECOM computer operator. Then verify that the following information is entered in 
the SAFECOM SC9000 computer account for the specific SC3100 you are working on. 
You must build an account into the SAFECOM SC9000 computer before the computer will recognize and place 
on-line a unit in the field. Below is a summary of the parameters necessary to program an SC3100 account into 
the SAFECOM computer. This is the first setup menu. These parameters must be entered, then “PG DOWN”  to 
the second menu. A summary of the second setup menu can be found on the following page. The parameters 
that must be programmed by the Central Station are denoted in the following illustration and are summarized 
below: 
 
 
 
02/12 10:45:57 
F1= Copy 
 
           PGDN= More Setup 
F2=Delete 
 
          
F9=Help
 
 I     SAFECOM ST1000 v2.42     I 
 02/12 09:12:22     122>STARTUP 
 02/12 09:13:26     301>AC TROUBLE 
 02/12 09:14:42     152>ALARM ZONE2 
 02/12 09:15:57     202>2133   E1 
 
     TX   RX   MODE   HP 
              **    - - - - - 
 
SAFECOM SC9000 COMPUTER
 
*
SELECT | REMOTE 456 | SETUP 1 
 
 S/N: 
 
PID: 
 
 Framer: 
      Channel: 
 
 Poll Interval:        :        :         
 
 Vline: 
     Vaccount: 
 
 Notes: 
 
 
 
 
 
Figure 6:  System Parameters 
• 
S/N: 
This number must match the CPU Serial Number listed on the label of the SAFECOM SC3100. 
• 
PID: 
This number must match the PID number on the label of the SAFECOM SC3100. 
• 
Framer: 
This should correspond to the framer that is to be assigned to this unit. 
• 
Poll Interval: 
This is the time in hours :  minutes :  seconds  that the unit in the field is to be polled by the 
Central Station. 
• 
Vline: 
The number placed here will report to the Automation System as coming in from “line XX” 
• 
Vaccount: 
The number placed here will report to the Automation System as signal coming from “account 
XXXX”. 
• 
Notes: 
This area is used to note the account information such as: Address, Customer, Account #, Install 
date, etc.