Blodgett BLP-40G Manual De Usuario

Descargar
Página de 17
4
1.0  SERVICE CONNECTIONS
1.0 [26]
29.5 [750]
6[152] MINIMUM
23.5 [597]
OPTIONAL FAUCET
POUR PATH
C
A
33
[838]
37
[940]
H
H
K
H
4.0 [101]
7.0 [178]
L
M
B
19.25
[489]
D
E
F
G
J
REAR FLANGED FOOT DETAIL
4
7/16" [11mm] HOLES
ON 3 [76] B.C.
 EQUALLY SPACED
Ø
DIMENSIONS ARE IN INCHES [MM]
Unless otherwise specified, Field Wire Electrical Connection to be 120 Volts, 60 Hertz single phase with grounding
GAS CONNECTION: Supply gas through 3/4" pipe. A gas shut-off valve must be installed in supply piping convenient and adjacent to appliance.
COLD WATER: 3/8" O.D. tubing to faucet. (OPTIONAL)
HOT WATER: 3/8" O.D. tubing to faucet. (OPTIONAL)
152 litres
40 gallons
114 litres
30 gallons
1880
74
1156
45.5
851
33.5
1219
48
914
36
DIMENSIONS
13
330
13
330
28
711
28
711
12.5
318
12.5
318
15.5
394
14
356
4
102
4
102
32
813
13.88
352
6
152
6
152
1105
851
43.5
33.5
610
24
610
24
1880
74
BLP-40G
BLP-30G
MODEL
CAPACITY
inches
mm
inches
mm
A
B
C
D
E
F
G
H
J
K
L
M
UNITS
MODEL
BLP-30G
BLP-40G
SUPPLY PIPE PRESSURE (W.C.)
GAS SUPPLY
7"-14" (178-356mm)
Natural
80,000
100,000
BTU/HR.
23.4
29.3
kW/HR.
11"-14" (279-356mm)
Propane