4 — MAINTENANCE 
 
4-9 
Cylinder Disassembly and Inspection 
Perform the following procedure to disassemble the upper or lower hydraulic lift cylinder. 
Whenever the hydraulic cylinder is disassembled, all seals must be replaced. Refer to 
replacement seal kit, Figure 6-3 or 6-4. 
1.  Check bearings (1, Figure 4-6) for wear and excess play. Replace bearings if 
necessary. 
2.  Unscrew headstock (2) and slide cylinder rod (3) from housing (4). 
3.  Remove slotted nut (5) and piston (6). Remove and discard wear ring (7), o-rings 
(8 and 9). Remove sleeve (10). 
 
Figure 4-6.  Hydraulic Cylinder Repair 
 
1.  Bearings 
 
2.  Headstock 
 
3.  Cylinder Rod 
 
4.  Housing 
 
5.  Slotted Nut 
 
6.  Piston 
 
7.  Wear Ring  
 
8.  O-Ring 
 
9.  O-Ring 
 
10.  Sleeve 
 
11.  O-Ring 
 
12.  Backup Ring 
 
13.  Seal 
 
14.  Bushing 
 
15.  Wiper