Bil-Jax Wheelchair XLB-4232 DC Manual De Usuario

Descargar
Página de 116
XLB-4232 DC 
 
4-12 
 
4-6 TROUBLESHOOTING 
Table 4-3.   Troubleshooting Chart 
Problem Cause 
Correction 
1.  Outriggers indicator lamp 
will not light up. 
a.  Master power switch turned off. 
b.  Emergency stop or power button 
engaged (pushed in). 
c.  All outriggers not deployed. 
d.  At least one wheel not raised. 
a.  Turn on master power switch. 
b.  Rotate emergency stop buttons 
clockwise to disengage. 
c.  Deploy all outriggers. 
d.  Raise at least one wheel off the 
ground. 
2.  Boom UP/DOWN and 
ROTATION functions do not 
work. 
a.  Master power switch turned off. 
b.  Low battery power. 
 
 
c.  Boom lift is out of level. 
d.  Emergency stop or power button 
engaged (pushed in). 
e.  Battery ground or in-series cable 
loose. 
f. 
 All outriggers not deployed 
 
g.  At least one wheel is not raised. 
 
h.  Battery cable or equipment ground 
lead loose or corroded. 
i. 
Hydraulic pump not pumping. 
a.  Turn on master power switch. 
b.  Check battery charge LEDs on upper 
control panel. Recharge batteries if 
yellow or red LED is lighted. 
c.  Level boom lift with outrigger jacks. 
d.  Rotate emergency stop button 
clockwise to disengage. 
e.  Check for and repair loose battery 
connections or ground fault. 
f. 
Check outrigger display. Lower 
outrigger jacks to engage switches. 
g.  Check outrigger display.  Raise at 
least one wheel off the ground. 
h.  Clean and reconnect loose or corroded 
battery cable or ground lead. 
i. 
Check pump motor operation; repair 
or replace if not running. Check gear 
pump; replace if hot to touch. 
3.  Single boom lift or rotation 
function does not work.  
a.  Loose wiring connector. 
 
 
b.  Valve solenoid not operating 
properly. 
c.  System interlock fault. 
 
d.  Broken or loose wire. 
a.  Check wiring terminals in control box 
and at valve manifold; repair loose 
wiring terminal. 
b.  Swab out valve solenoids and recheck 
function; replace solenoid if faulty. 
c.  Check display for system status. 
Correct indicated fault conditions. 
d.  Repair or replace wire. 
4.  Boom lift and rotate 
functions do not operate 
properly. 
a.  Valve solenoid not operating 
properly. 
b.  Loose solenoid wiring. 
 
 
a.     Swab out valve solenoids and recheck 
function; replace solenoid if faulty. 
b.  Check wiring terminals in control box 
and at valve manifold; repair loose 
wiring terminal.