Immersion Well or 2-in-1 Sensor
Mount the control by aligning the 7/8” diameter hole 
(found on back) around the mating feature of the 
immersion well or 2-in-1 sensor and press into 
place.  Position the control upright and tighten down 
the #10 screw located on the left side of the control.  
Tighten so that control is securely in place
 
(Figure 9)
.
Plug the temperature sensor lead terminal into the 
receptacle on the control base.  See Figure 10.
Appliance Surface
Use the AquaSmart mounting template to locate the 
mounting holes in a desired location on mounting 
surface.  The template can be found in the back of 
this manual.
Use (3) #8 x 3/4” self drilling screws (.110 hole 
diameter if pre-drilling) included in the installation 
kit.  Run screws into mounting surface, leaving a 
1/4” space between bottom of screw head and 
mounting surface.
Open the cover of the AquaSmart control to expose 
key hole locations in plastic case.  Align key holes 
over mounting screws and secure in place.
Plug the temperature sensor lead terminal into the 
receptacle on the control base.  See Figure 10.
If necessary, use the 48” cable extension to connect 
sensor to control base. Refer back to Figure 3.
1.
2.
1.
2.
3.
4.
5.
Installing the AquaSmart Control 
(Refer back to Figure 3 for appropriate mounting method).
Figure 9 - Mounting Clamp and Screw for Immersion Well
For clarity, the printed circuit board is not shown.
Figure 10 - Temperature Sensor Lead/Receptacle 
Wiring
Electrical Shock, Fire, 
Explosion and Burn Hazards
This control must be installed, adjusted and put 
into operation only by a trained, licensed, qualifi ed 
professional or service agency in accordance with 
the latest revision of the National Electric Code ANSI/
NFPA 70 (Canada CSA C22.1) state, local codes and 
authorities having jurisdiction.
Follow the appliance manufacturer’s wiring diagrams 
and note all safety controls.
Typical safety controls include high temperature or 
pressure limits, low water cutoffs, anti-scald valves, 
pressure relief valves and water feed valves.
Verify all limits and safety controls are installed and 
functioning correctly, as specifi ed by the appliance 
manufacturer, applicable safety standards, codes 
and all authorities having jurisdiction.
Provide ground wiring to the appliance, burner and 
controls.
y
y
y
y
Electrical Shock Hazard. 
Can Cause Severe Injury, 
Death, or Equipment Damage.
Disconnect power before wiring to prevent electrical 
shock or equipment damage.
All wiring must comply with local electrical codes and 
ordinances.  The limits given in the specifi cations 
section must not be exceeded when applying this 
control.  Terminals on the AquaSmart are approved for 
copper wire only.
Refer to the label on the inside of the AquaSmart door or 
to Technical Specifi cations in this manual for Electrical 
ratings and maximum load information.  Use manufacturer 
instructions when wiring controlled equipment or refer to 
typical hookups in Figure 12 through Figure 17.
More than one service switch may be needed to 
disconnect all power to the AquaSmart.  The optional 
power disconnect switch interrupts power to the 
AquaSmart control.  Depending on system wiring, some 
terminals and connections (most notably ZR and the input 
to the optional power disconnect switch) may still be live.
y
y
y