White Rodgers 1F95-0671 Emerson Blue 6" Programmable Thermostat Hoja De Especificaciones

Descargar
Página de 2
Size:  8.5" x 11"
Job #:  WRDG_134066
File Name:  134066_1F95_0671_Single_SS.ai
Printing & Finishing:  4/C Offset
Colors: 
C
M
Y
DIE
Printout Size
100%
Updates:  jd08.05.11, ks08.08.11, 
nf 082511, BBpff9.15.11
This printout is for indicating 
color breaks only. 
Do not use for color matching.  
Do not measure for accuracy.
Revision:  4
Time:
 
1 0 a
WR-5286-1
www.white-rodgers.com
www.emersonclimate.com
Markham, Ontario
905-948-3411
Saint Louis, Missouri
314-553-3600
The Emerson logo is a trademark and
a service mark of Emerson Electric Co.
2/2
4/2
Single
Stage
Multi-
Stage
Heat
Pump
Stages
Heat/Cool
by System
Program
Options
Model
Number
Model
Selectable Performance Features
Comfort and Convenience Features
Applications
Power Source
1/1
7,5+1+1,Ø
B,H
PA
3 Wire Zone Valve 
Millivolt Compatible
✓ ✓
Display Size – Square Inches
Humidity Control
(H)Humidity / (D)Dehumidity
Programmable Fan
Comfort Circulating Fan
Dual Fuel Heat Pump Control
(L)Logic / (O) Outdoor Sensor
Dual Fuel Heat Stages
HP/Gas
Auto Changeover
Gas/Oil/Electric
Lighted Display
***
One Button Programming
Audible Feedback
Alkaline Battery Life (Years)
5
Cool Savings
Setpoint Temperature Limits
Adjustable Max. / Min.
Periods
Per Day
Options
4,2,Ø
1F95-0671
Universal
Outdoor Remote Sensor
1
Energy Mgt. Recovery
Keypad Lockout
(T)Total / (P) Partial
T,P
Program Override
(AV)Adjustable Variable
(V)Variable, (P)Program, (2)2 Hour
2
Indoor Remote Sensors
Max. Number + Thermal Average
and/or Weighted
1 + 1
Daylight Savings Adjustment
(A) Auto/(B) Button
A
Furnace Lockout
Ignition Model Reset
Memory Backup
(P)Permanent /(B) Battery
P
6
O
2,2
Warranty (Years)
5
Programs
B =Battery, H =Hardwired, PA =Power Stealing Assist     *** Optional Continuous Display Light w/Hardwire Connection     
 Only One (1) Remote Sensor May Be Used – Either Indoor or Outdoor; or Logic Program and Indoor Remote Sensor
Dimensions
4.2"H x 6.4"W x 1.7"D
Thermal Specifications
Setpoint Temperature Range: 
45° to 99°F (7° to 37°C)
Rated Differential: Heat 0.6°F; Cool 1.2°F
Operating Ambient Temperature: 
32° to 105°F (0° to 41°C)
Operating Humidity Range: 90% 
non-condensing maximum
Shipping Temperature Range: 
-40° to 150°F (-40° to 65°C) 
Electrical Specifications
Rating
Battery Power: mV to 30 VAC, 
NEC Class II, 50/60 Hz or DC
Input Hardwire: 20 to 30 VAC
1.5 Amps (load per terminal)
2.5 Amps maximum load (all terminals combined)
Standard Systems
Single Stage gas, oil, electric
Single Stage heat pump
Millivolt Systems
Multi-Stage gas, oil, electric
Multi-Stage heat pump
Accessories
Remote Sensors:
 Indoor 
– 
F145-1328
 Outdoor 
– 
F145-1378
Thermostat Guards:
  Clear – F29-0198
  Metal – F29-0220 (solid base)
Wallplates:
  F61-2600 (8.1"W x 5.4H")
  F61-2634 (6.5"W x 5"H)
For Additional Information 
Visit www.white-rodgers.com
Exclusive Blue 6" Features
 
Large, 6-square-inch Blue
 display 
with easy-to-see characters
Quick one-button programming
(See Automatic Schedule section in 
installation instructions)
Configures as manual heat/cool, auto 
changeover, heat only or cool only
Exclusive battery power monitor
5-year warranty
Display
Large, 6-square-inch display
Blue, lighted display for 
easier low-light viewing
Larger, easy-to-read character size
Large buttons for easy operation
Programming
 
Universal – installer selectable 
system applications
Choice of 7-day, 5/1/1 day 
programmable or non-programmable 
(installer selectable)
4 time and 4 temperature settings 
per program (2 setbacks) heat and 
cool, or selectable – 2 time and 2 
temperature settings (1 setback)
Energy savings up to 33%
Patented pre-programmed schedule 
simplifies time and temperature 
programming
Comfort & Convenience
Intuitive menu-driven setup, 
programming and operation, with 
audio prompt to confirm entries
Permanent program retention 
during power loss
Indefinite setpoint Hold or 
temporary temperature override
Temporary temperature override will 
override program for two hours
Auto heat/cool changeover option –
automatically switches between 
heating and cooling programs
Heating and cooling, heating only 
or cooling only configuration 
(installer selectable)
Setpoint temperature 
“limited range” capable
Furnace filter change reminder
Maintains room temperature to 
within +/- 1°F
Room temperature display can be 
recalibrated up to +/- 4°F
Performance
Choice of battery powered with 
optional power stealing assist or 
hardwired with battery backup
Selectable Energy Management 
Recovery
Meets California Building Code, 
Title 24
Fast (FA) or slow (SL) heating cycle 
anticipation
Exclusive “Call for Service” 
diagnostic indicator
Compressor lockout protection
Millivolt compatible
Electric heat option
BLUE
 
6"
 
Universal Thermostat
1F95-0671
Universal
RC RH
W2
W/E
Y2
Y
6
L
+
S
C
1F95-0671
7-Day or 5/1/1 Day Programmable or 
Non-Programmable Thermostat
• For SS, MP and HP Systems  •  7-Day or 5/1/1 Day Programmable or Non-Programmable  •  Hardwired or Battery Powered
Terminal
Designations