3. 
Connect the “DC”  charger plug to the 
connector  on  the  machine. 
NOTE  A 
safety  override  switch  is  activated 
when the “ D C  charge plug is connected. 
This prevents all panel circuits on the 
machine  from  accidentally  being 
switched on during charging cycle. 
4. 
Connect charger “AC”  plug to properly 
rounded outlet that  has correct voltage 
or the charger. 
5.  The  charger  suppled  by  Wlndsor  is 
totally  automatic  and  shuts  off  when 
the batteries are fully charged. 
Refer to the charger manual for 
detailed charging information. 
6.  After  charging  check  electrolyte  level 
of  the batteries.  Add distilled water  to 
the level as shown in diagram. 
FROM 
BOTTOM 
OF TUBE 
BATTERY  MAINTENANCE 
1.  Keep tops  of  batteries clean and dry. 
Use a damp cloth with a weak solution 
of baking soda or ammonia and water. 
Use a clean  dry  cloth to wipe  battery 
tops dry after cleaning. 
2.  If  corrosion  (white  deposits)  appears 
on  the  battery  terminals  and  cable 
clamps,  remove and clean.  Use a battery 
terminal and connector cleaning tool. 
TERMINAL CLEANER 
3.  Keep  the  battery  electrolyte  at 
correct  level 
approximately 
below bottom of filler tube of  each cell. 
Distilled  water  should  be  added,  as 
needed, 
AFTER charging cycle. 
WARNING: 
Do not 
electrolyte 
level to drop below the tops of the plates. 
SERVICING  THE 
COMPACT SCRUBBER 
CAUTION: 
Before  making  any  adjust- 
ments or repairs to the machine. 
. . 
1.  Only  qualified  maintenance  personnel 
are 
to 
perform repairs. 
2.  Make  sure  battery  charger  is  discon- 
nected. 
3.  Make sure all switches are “OFF”. 
4. 
Remove batteries as  required or  discon- 
nect main battery leads from  batteries 
when making repairs to electrical system. 
5.  Refer to wiring diagram when replacing 
electrical  parts  or  repairing electrical 
system. 
VACUUM MOTOR 
1.  Disconnect  battery  leads  and  remove 
batteries from compartment. 
2.  Remove (6) screws holding 
motor/ 
plate assembly to recovery tank. 
3.  Disconnect 
motor  lead from  con- 
nector  and  lift  out 
assembly. 
4.  Check  motor  brushes.  When  worn  to 
replace both brushes. 
PUMP 
ASSEMBLY 
(On models equipped with auxiliary  pump) 
1.  Remove  batteries  and  squeegee  as- 
sembly. Lay machine on side. 
2. 
Disconnect  pump  motor  leads.  Re- 
move 
(4) 
screws  holding  pump  to 
chassis.  Disconnect  solution  hoses 
from  pump  head  and  lift  out  pump. 
Refer  to  pump  drawing  for  replace- 
ment parts. 
CAUTION: 
When  replacing 
barbs on pump head-DO NOT 
TIGHTEN-as  this  could  crack  intake 
and exhaust ports in pump head. 
SQUEEGEE ASSEMBLY 
To remove squeegee assembly. 
1. 
Raise squeegee 
arm to store position. 
2.  Remove 
hose from squeegee. 
3. 
Pull  retaining  pin  from  locator  stud. 
Push down  and slide  squeegee to the 
right to disengage right hand stud from 
drag arm. 
4.  When installing or replacing squeegee 
blades make sure the 
smooth 
of  the 
blade is next to the squeegee casting. 
5.  The  an 
of  the  squeegee  can  be 
the adjusting screw. Turn 
screw  clockwise  to 
squeegee  for- 
ward and counterclockwise to tilt rear- 
ward.  Tighten  lock  nut  after  making 
adjustment. 
6.  Down  pressure  can  be  increased  or 
decreased with the adjusting nut.