White Rodgers BLUE 2 SINGLE STAGE 1F86-0244" Manual De Usuario

Descargar
Página de 16
2
INSTALLATION 
REMOVE OLD THERMOSTAT
1.  Shut off electricity at the main fuse box until installation is 
complete. Ensure that electrical power is disconnected.
2.  Remove  the  front  cover  of  the  old  thermostat.  With 
wires  still  attached
,  remove  wall  plate  from  the  wall.  If 
the old thermostat has a wall mounting plate, remove the 
thermostat and the wall mounting plate as an assembly.
3.  Identify each wire attached to the old thermostat using 
the labels enclosed with the new thermostat.
4.  Disconnect the wires from old thermostat one at a time. DO 
NOT LET WIRES FALL BACK INTO THE WALL.
5.  Install new thermostat using the following procedures.
ATTENTION!
This product does not contain mercury. However, this product 
may replace a unit which contains mercury.
Do  not  open  mercury  cells.  If  a  cell  becomes  damaged,  do 
not touch any spilled mercury. Wearing nonabsorbent gloves, 
take up the spilled mercury and place into a container which 
can be sealed. If a cell becomes damaged, the unit should be 
discarded.
Mercury  must  not  be  discarded  in  household  trash.  When 
the unit this product is replacing is to be discarded, place in 
a  suitable  container.  Refer  to  www.white-rodgers.com  for 
location to send the product containing mercury.
ATTACH THERMOSTAT BASE TO WALL
1.  Remove the packing material from the thermostat. Gently 
pull the cover straight off the base. Forcing or prying on the 
thermostat will cause damage to the unit.
2.  Place  base  over  hole  in  wall  and  mark  mounting  hole 
locations on wall using base as a template (see Fig.1).
3.  Move base out of the way. Drill mounting holes.
4.  Push wires through opening in thermostat base.
5.  Fasten  base  loosely  to  wall  using  two  mounting  screws. 
Place  a  level  against  bottom  of  base,  adjust  until  level, 
and then tighten screws. (Leveling is for appearance only 
and will not affect thermostat operation.) If you are using 
existing mounting holes, or if holes drilled are too large and 
do not allow you to tighten base snugly, use plastic screw 
anchors to secure subbase.
6.  Connect  wires  to  terminals  on  base  using  appropriate 
wiring schematic (see figs. 2 through 4).
7.  Push excess wire into wall and plug hole with a fire-resistant 
material  (such  as  fiberglass  insulation)  to  prevent  drafts 
from affecting thermostat operation.
O/B TERMINAL SWITCH SELECTION
The  O/B  switch  on  this  thermostat  is  factory  set  to  the  “O” 
position.  This  will  accommodate  the  majority  of  heat  pump 
applications,  which  require  the  changeover  relay  to  be 
energized in COOL. If the thermostat you are replacing or the 
heat pump being installed with this thermostat requires a “B” 
terminal, to energize the changeover relay in HEAT, the O/B 
switch must be moved to the “B” position.
Mounting
Hole
Mounting
Hole
Opening
for wires
Gas/Elec
Switch
Battery
Door
O/B
Switch
Figure 1. Thermostat Base
GAS / ELEC SWITCH
If your system is a heat pump, the GAS/ELEC Switch must be 
set to ELEC (see Fig. 1) If your system is a single stage, the 
switch must be set to GAS. The switch setting must agree with 
the system configuration selected in the configuration menu.
BATTERY LOCATION
“AA” Alkaline Batteries
Two  “AA”  alkaline  batteries  are  installed  in  your  thermostat 
with  a  battery  tag  to  prevent  power  drainage.  Prior  to  use, 
open the battery door and remove the battery tag. To open, 
pull the battery door as shown by the arrow and lift open. The 
two “AA” batteries will operate all functions or maintain time 
and continuously display the temperature during a loss of AC 
power.  To  replace  batteries,  pull  the  battery  door  shown  by 
the arrow and lift open. Using the polarity indicated inside the 
battery  door,  insert  the  batteries.  To  close  the  battery  door, 
swing  the  door  down  while  pulling  in  the  direction  of  arrow. 
Once fully down, snap the door back into position.
Thermostat can be powered by system AC power or Battery. If 
 is displayed, the thermostat is battery powered. If 
 is not 
displayed, thermostat is system powered with optional battery 
back-up. When battery power remaining is approximately half, 
the 
 will be displayed. When “Change 
” is displayed, 
install  fresh  “AA”  alkaline  batteries  immediately.  For  best 
results,  use  new  premium  brand  alkaline  batteries  such  as 
Duracell® or Energizer®. We recommend replacing batteries 
every 2 years. If the home is going to be unoccupied for an 
extended  period  (over  3  months)  and 
  is  displayed,  the 
batteries should be replaced before leaving. When less than 
two months of battery life remain, the setpoint temperature will 
offset by 10 degrees (10 degrees cooler in Heat mode / 10 
degrees warmer in Cool mode). If offset occurs, the normal 
setpoint can be manually reset with 
 or 
. Another offset 
will  occur  within  two  days  if  batteries  are  not  replaced.  To 
replace the batteries, set system to OFF.