SPECIFICATIONS
ELECTRICAL RATINGS [@ 77
°
F (25
°
C)]:
Input Voltage: 25 VAC 50/60 Hz
Max. Input Current @ 25 VAC: 0.455 amp
Max. Input Current @ 25 VAC: 0.455 amp
Relay Load Ratings:
Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf
Ignitor Relay: 2.0 amp @ 120 VAC 50/60 Hz
Ignitor Relay: 2.0 amp @ 120 VAC 50/60 Hz
(resistive)
Flame Current Requirements:
Minimum current to insure flame detection: 1
µ
a DC*
Maximum current for non-detection: 0.1
µ
a DC*
Maximum allowable leakage resistance: 100 M ohms
*Measured with a DC microammeter in the flame probe
lead
lead
OPERATING TEMPERATURE RANGE:
-40
°
to 175
°
F (-40
°
to 80
°
C)
HUMIDITY RANGE:
5% to 93% relative humidity (non-condensing)
MOUNTING:
Surface mount multipoise
Timing Specs: (@ 60 Hz)
maximum
Flame Establishing Time:
2 sec
Flame Failure Response Time:
2 sec
Gases Approved: Natural, Manufactured, Mixed, Liquid
Petroleum, and LP Gas Air Mixtures are all approved for
use.
Petroleum, and LP Gas Air Mixtures are all approved for
use.
TIMING SPECIFICATIONS
(All times are in seconds, unless noted otherwise)
PRE-PURGE
TRIAL FOR IGNITION
PERIOD
PERIOD
IGNITION ACTIVATION
PERIOD
PERIOD
RETRIES
VALVE SEQUENCE
PERIOD
PERIOD
INTERPURGE
POST-PURGE
LOCKOUT TIME
HEAT DELAY-TO-FAN-ON
HEAT DELAY-TO-FAN-OFF*
COOL DELAY-TO-FAN-ON
COOL DELAY-TO-FAN-OFF
IGNITOR WARM-UP
HUMIDIFIER
ELECTRONIC AIR
CLEANER
CLEANER
15
4
4
4 times
12
15
5
122
45
60/90/
120/180
0
0
20
YES
YES
50A62-820
* This time will vary depending on option
switch position. The control is factory-set
at 60 sec. heat delay-to-fan-off. See
OPERATION section for further
information.
at 60 sec. heat delay-to-fan-off. See
OPERATION section for further
information.