Symptom 
Possible Cause 
Corrective Action
 
 
No Cool 
1.  SYSTEM Switch not set to COOL 
Set SYSTEM Switch to COOL and lower setpoint    
 
   
below room temperature.
 
2.  Loose connection to thermostat or system. 
Verify thermostat and system wires are securely  
 
  
 
attached.
 
3.  Cooling System requires service or thermostat 
Same procedure as diagnostic for No Heat  
 
  requires replacement. 
condition except set the thermostat to COOL and  
 
   
lower the setpoint below the room temperature.  
 
   
There may be up to a fi ve minute delay before  
 
 
   
the thermostat clicks in Cooling if the compressor   
 
   
lock-out option is selected in the confi guration  
 
 
   
menu (Item 6).
Heat, Cool or Fan Runs Constantly. 
1.  FAN Switch set to Fan ON. 
Check each wire connection to verify they are
 
2.  Possible short in wiring. 
not shorted or touching together. No bare wire
 
3.  Possible short in thermostat. 
should stick out from under terminal screws.
 
4.  Possible short in Heat/Cool/Fan system. 
Try resetting the thermostat. If the condition 
 
   
persists the manufacturer of your system or
 
   
service person can instruct you on how to test the
  
   
Heat/Cool system for correct operation. If the
 
   
system operates correctly, replace the thermostat.
Furnace Cycles Too Fast or Too Slow 
1.  The location of the thermostat and/or the size 
Item 2 in the Confi guration Menu is the adjustment    
(narrow or wide temperature swing) 
  of the Heating System may be infl uencing the 
that controls the cycle rate. If an acceptable cycle
  
cycle 
rate. 
rate is not achieved using the FA (Fast) or SL  
 
 
   
(Slow) adjustment contact a local service person
 
   
for additional suggestions.
Cooling Cycles Too Fast or Too Slow 
1.  The location of the thermostat and/or the size  
The cycle rate for cooling is fi xed and can not be
(narrow or wide temperature swing) 
  of the Cooling System may be infl uencing the 
adjusted. Contact a local service person for
  
  cycle rate. 
suggestions.
Thermostat Setting and Thermometer 
1.  Thermostat thermometer setting requires 
The thermometer can be adjusted +/- 4 degrees as
Disagree  
   adjustment.  
listed in item 7 of the Confi guration Menu. No other
 
   
adjustment is possible.
Clock Loses or Gains Time 
1.  Loss of power to thermostat and low batteries. 
The thermostat will maintain its program in memory  
 
   
even with no power/no batteries but the clock time  
 
   
will be incorrect when power is restored. See No  
 
   
Heat/No Cool/No Fan (common problems) above    
 
   
for items to check in the system.
Heat or Cool Starts Early  
1.  EMR activated 
See Confi guration Menu (Item 4).
Thermostat Does Not Follow Program   1.  AM or PM set incorrectly in program. 
Check current clock and program settings including
 
2.  AM or PM set incorrectly on the clock. 
the AM or PM designations for each time period.
 
3.  Voltage spike or static discharge. 
If a voltage spike or static discharge occurs use the
 
   
Reset Operation listed above.
Blank Display and/or Keypad Not   
1.  Loss of power and dead batteries. 
Replace batteries and check heat/cool system for
Responding 
2.  Voltage Spike or Static Discharge. 
proper operation. If a voltage spike or static  
 
 
   
discharge occurs use the Reset Operation  
 
  
 
listed 
above.
TROUBLESHOOTING
www.white-rodgers.com
St. Louis, Missouri
Markham, Ontario
White-Rodgers is a division
of Emerson Electric Co.
The Emerson logo is a 
trademark and service mark
of Emerson Electric Co.
HOMEOWNER HELP LINE:  1-800-284-2925