White Rodgers 21D28-6 Evaporative Cooling Kit Catálogo

Descargar
Página de 1
SPECIFICATIONS
Electrical Ratings:
Pilot Duty Pole  . . . . . . . . . . . . . . . . . . . . .   3 VA at 24 VAC (Minimum)
                                                                     25V at 24 VAC (Maximum)    
Input Voltage. . . . . . . . . . . . . . . . . . . . . . .   24 VAC nominal
Total Power Consumption. . . . . . . . . . . . .   0.5 VA (relay de-energized)
                                                                    4.0 VA (relay energized)
57T01-843 BLOWER TIME DELAY RELAY
The 57T01-843 Time Delay Relay is for Use in Air Handlers Installed 
in Compressor-Run Air Conditioning and Heat Pump Systems to 
Delay the Blower Shut-Off After the Compressor has Shut Off. 
Replaces Trane Part Numbers D155079P01 and RLY 2807
FEATURES
• Allows residual cooled air to be blown into the controlled space, increasing the
 efficiency of the system in cooling.
• Depending on electrical hookup in a heat pump system, delay of blower shut-off
  could also occur in heating.
Model Number
Contact Ratings:
Power Pole (Amperes per pole)-
57T01-843
208/240/277 VAC
Full Load
7
Locked Rotor
36
Resistive
15
U.L. Approved Horsepower
3
/
HP
57T01-843
57T01-843 BLOWER
TIME DELAY RELAY
www.white-rodgers.com
84
COOLING / 
REFRIGERA
TION