EMR (Energy Management Recovery)
Default is
on
. With EMR selected
on
,
the heating or cooling system will start
early so the temperature in your home
is at the desired temperature at the
beginning of the program period. If set
to
early so the temperature in your home
is at the desired temperature at the
beginning of the program period. If set
to
Off
, the system will not start until
the beginning of the program period.
Cycle Humidifier
– Default if
Off
. This
feature provides an option that reduc-
es the water usage by up to 50% when
a flow-through humidifier is controlled
by the thermostat. It is recommended
for use on flow-through humidifiers
only. When turned
es the water usage by up to 50% when
a flow-through humidifier is controlled
by the thermostat. It is recommended
for use on flow-through humidifiers
only. When turned
on
, the humidifier
will cycle to turn off for 10 minutes
after it has run for 10 minutes. The
blower and/or furnace will continue to
run during the humidifier off period.
after it has run for 10 minutes. The
blower and/or furnace will continue to
run during the humidifier off period.
Auto Humidity Reduction
– Default is
Off
. When selected,
High
or
Low
pro-
vides the ability to minimize or reduce
the window condensation by reducing
the humidity setpoint when the outside
temperature is cold.
the window condensation by reducing
the humidity setpoint when the outside
temperature is cold.
Comfort or Dehum
– Default is
Off
.
When
Comf
option is selected the
temperature is altered by the humidity
to reflect the true comfort. When
to reflect the true comfort. When
Dehum
is selected humidity reduction
is maximized by continuing to cool
below the temperature setpoint.
below the temperature setpoint.