EMR (Energy Management Recovery)
Default is 
on
. With EMR selected 
on
the heating or cooling system will start 
early so the temperature in your home 
is at the desired temperature at the 
beginning of the program period. If set 
to 
Off
, the system will not start until 
the beginning of the program period.
Cycle Humidifier
 
– Default if 
Off
. This 
feature provides an option that reduc-
es the water usage by up to 50% when 
a flow-through humidifier is controlled 
by the thermostat. It is recommended 
for use on flow-through humidifiers 
only. When turned 
on
, the humidifier 
will cycle to turn off for 10 minutes 
after it has run for 10 minutes. The 
blower and/or furnace will continue to 
run during the humidifier off period.
Auto Humidity Reduction
 
– Default is 
Off
. When selected, 
High
 or 
Low
 pro-
vides the ability to minimize or reduce 
the window condensation by reducing 
the humidity setpoint when the outside 
temperature is cold.
Comfort or Dehum
 
– Default is 
Off
When 
Comf
 option is selected the 
temperature is altered by the humidity 
to reflect the true comfort. When  
Dehum
is selected humidity reduction 
is maximized by continuing to cool 
below the temperature setpoint.