White Rodgers 1F97-0671 Manual De Usuario

Descargar
Página de 12
3
Single Stage 
System
RC
RH
C
Y*
W*
G
O/B
6
L
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
Call for heat
24 volt 
power for 
cooling
24 volt 
power for 
heating
24 volt 
common 
(optional for 
system 
operation, 
required for 
remote 
sensor and 
system status 
indicator)
Call for cool
Blower/Circulator fan
energized on a call 
for cool or Fan On
(also energized in
heating if configured
for Electric Heat)
Installer
Configuration
Menu selects 
“O” or “B” for 
changeover
function. Set 
to “O” terminal
energized in Cool
& Off mode. Set 
to “B” terminal
energized in Heat
Power closed
connection for
SPDT 3-wire
zone valve
System
status
Indicator for 
sytems
with “L” terminal
connection
WIRING CONNECTIONS
Refer to equipment manufacturers' instructions for specifi c 
system wiring information. After wiring, see CONFIGURA-
TION section for proper thermostat confi guration.
Wiring diagrams shown are for typical systems and describe 
the thermostat terminal functions.
TERMINAL DESIGNATION DESCRIPTIONS 
Terminal Designation        Description
    O/B ........................................... Changeover valve for heat pump energized constantly in cooling and off/heating
 Y 
............................................ Compressor 
Relay
 G 
............................................ Fan 
Relay
 
RC ............................................ Power for Cooling
 
RH ............................................ Power for Heating
 
C ............................................ Common wire from secondary side of cooling (Optional). Required for fault indication, continuous back-
                                                       light operation or remote temperature sensor operation
       W ........................................... Heat Relay (Stage 1) 
 
- ............................................ Common (DC) for wired remote temperature sensor
 
S ............................................ Frequency signal from remote temperature sensor
 
+ ............................................ Power (DC) to remote temperature sensor
 
L ............................................ Compressor diagnostic indicator for systems with diagnostic connection typically found on Heat pump 
                                                       systems or with Copeland's Comfort Alert
WIRING DIAGRAMS
Figure 2 – Single Stage or Heat Pump with no Auxiliary Heat with Single Transformer
Single Stage Connections
Refer to equipment manufacturers' 
instructions for specifi c system 
wiring information.
This thermostat is designed to 
operate a single-transformer or 
two-transformer system.
This thermostat is confi gured for 
use with the following fossil fuel 
systems: 
SINGLE STAGE
 gas, oil or 
electric.
After wiring, see INSTALLER 
CONFIGURATION section for 
proper thermostat confi guration.
*Jumper Y to W required for heat pump systems not compatible with heat pump systems that 
require an auxiliary heat output.
Figure 3 – Single Stage System (No Heat Pump) with Two Transformers
NOTE: If continuous backlight or 
hardwired power input are desired 
but do not function in both HEAT 
and COOL modes, cut the heating 
transformer 24V wires and tape off. 
Connect the neutral circuit discon-
nected from the heating transformer 
to the neutral circuit of the cooling 
transformer. Disconnect the wire to 
the RH terminal and install a jumper 
between RH and RC. Depending on 
the system requirements, replace 
the cooling transformer with a 75VA 
class II transformer if needed.
Single
Stage
System
RC
RH
C
Y
W
6
L
Call for heat
24 volt 
power for 
cooling
24 volt 
power for 
heating
24 volt 
common 
(optional 
for system 
operation, 
required 
for remote 
sensor)
Heat mode-1st
stage,
Cool mode-1st
stage,
(Compressor)
G
Blower/Circulator fan
energized on a call 
for cool or Fan On
(also energized in
heating if configured
for Electric Heat)
O
Installer
Configuration
Menu selects 
“O” or “B” for 
changeover
function. Set 
to “O” terminal
energized in Cool
& Off mode. Set 
to “B” terminal
energized in 
Heat 
Power closed
connection for
SPDT 3-wire
zone valve
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
COOLING
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
HEATING
120VAC
System
status
Indicator for 
sytems
with “L” terminal
connection
Single Stage
3-wire
Zone Valve
application
Blower/Circulator
Fan Energized
Opens
Valve
(4)
Constant
24 Volt
(Com-
mon)
24 Volt
(Hot)
Cool
System
6
Y
W
C
RC
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
24 Volt
(Hot)
Heat
(5)
RH
G
Jumper
Closes
Valve
(6)
Figure 4 – 3-Wire (SPDT) Heat Only Zone Valve Wiring