White Rodgers 25M01A-100 25M Gas Dryer Valves Catálogo
APPLIANCE VALVES
2500 SERIES REPLACEMENT GAS VALVE COILS
FEATURES
• Easy installation of replacement coil assemblies.
• Available for most popular models.
• Single or complete coil sets
F91-3890
F91-3889
Model
OEM
Number
Application
Description
Type
F91-3889 25M01A-xxx 120V/60Hz Secondary Coil Replacement for Used on Whirlpool, Electrolux,
25M Valve Individual Pack Secondary Coil
GE, Maytag, Speed Queen
F91-3890 25M01A-xxx
120V/60Hz Coil Replacement for
Used on Whirlpool, Electrolux,
Booster and Holding Coil
GE, Maytag, Speed Queen
25M01A-100 AND 25M01A-101
25M01A Series Gas Valves Combine a Gas Pressure Regulator with
Redundant and Main Solenoid Valves for Hot Surface Ignition (HSI)
Residential Gas Clothes Dryers. Two Models to Replace Virtually All
Whirlpool, Maytag, GE, Frigidaire, Electrolux, or Speed Queen Gas
Dryer Valves.
FEATURES
• Compact split coil design.
• Inlet/outlet screen.
• Field-adjustable regulator.
• Replaceable operating coils (no gas interruption).
• Outlet pressure tap.
• Both models packaged with the most popular main burner orifices to replace
many OEM models.
SPECIFICATIONS
Type of Gas . . . . . . . . . . . . . . . . . . . . . Natural or LP gas (conversion kit included)
Pressure Regulator Setting . . . . . . . . . Nat. Gas: 2.8” to 5.4” W.C.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LP Gas: 8.5” to 12.0” W.C.
Operating Ambient . . . . . . . . . . . . . . . . Temperature: 32° to 155°F
Max. Pressure Rating. . . . . . . . . . . . . . 14” W.C. (½ PSI) max.
Electrical. . . . . . . . . . . . . . . . . . . . . . . . 120 VAC, 60 Hz, .06 amps
1” P.D. Capacity . . . . . . . . . . . . . . . . . . 40,000 BTU/HR
PARTS AND ACCESSORIES
• F91-3889 — Replacement Coil (Secondary)
• F91-3890 — Replacement Coil (Boost/Hold)
25M GAS
DRYER VALVES
Model
Coil
Outlet Flow
Inlet/Outlet
Regulator
Number
Voltage
Direction
Size
Adjustment Range
25M01A-100
120 VAC
Right Angle Left
3/8” NPT X 11/32”
Nat. Gas: 2.8” to 5.4” W.C.
25M01A-101
120 VAC
Right Angle Right 3/8” NPT X 11/32”
LP Gas: 8.5” to 12.0” W.C.
(Conversion Kit Included)
Mounting Position – Control may be mounted in the following positions: horizontal, vertical or 90° of horizontal.
Do not mount upside down.
25M01A-101
www.white-rodgers.com
109
109