Refer to equipment manufacturers' instructions for specific
system wiring information. After wiring, see CONFIGURA-
TION section for proper thermostat configuration.
For wiring diagrams, see next page.
Wiring diagrams shown are for typical systems and describe
the thermostat terminal functions.
WARNING
!
Thermostat installation and all components of the
Thermostat installation and all components of the
Thermostat installation and all components of the
Thermostat installation and all components of the
Thermostat installation and all components of the
control system shall conform to Class II circuits per
control system shall conform to Class II circuits per
control system shall conform to Class II circuits per
control system shall conform to Class II circuits per
control system shall conform to Class II circuits per
the NEC code.
the NEC code.
the NEC code.
the NEC code.
the NEC code.
INSTALLATION
INSTALLATION
INSTALLATION
INSTALLATION
INSTALLATION
Battery Location
Battery Location
Battery Location
Battery Location
Battery Location
2 "AA" alkaline batteries are included in the thermostat at
the factory with a battery tag to prevent power drainage.
Remove the battery tag to engage the batteries.
To replace batteries, set system to OFF
OFF
OFF
OFF
OFF, remove thermostat
from wall and install the batteries in the rear along the top of
the thermostat (see Figure 1).
Remove Old Thermostat
Remove Old Thermostat
Remove Old Thermostat
Remove Old Thermostat
Remove Old Thermostat
A standard heat/cool thermostat consists of  three basic parts:
1. The cover, which may be either a snap-on or hinge type.
2. The base, which is removed by loosening all captive screws.
3. The switching subbase, which is removed by unscrewing
the mounting screws that hold it on the wall or adapter
plate. Bef
Bef
Bef
Bef
Befor
or
or
or
ore r
e r
e r
e r
e remo
emo
emo
emo
emoving wir
ving wir
ving wir
ving wir
ving wires fr
es fr
es fr
es fr
es from old ther
om old ther
om old ther
om old ther
om old thermosta
mosta
mosta
mosta
mostat,
t,
t,
t,
t,
label each wire with the terminal designation from
label each wire with the terminal designation from
label each wire with the terminal designation from
label each wire with the terminal designation from
label each wire with the terminal designation from
which it was attached
which it was attached
which it was attached
which it was attached
which it was attached. Disconnect the wires from the old
thermostat one at a time. Do not let wir
Do not let wir
Do not let wir
Do not let wir
Do not let wires f
es f
es f
es f
es fall bac
all bac
all bac
all bac
all back into
k into
k into
k into
k into
the wall
the wall
the wall
the wall
the wall.
Installing New Thermostat
Installing New Thermostat
Installing New Thermostat
Installing New Thermostat
Installing New Thermostat
1. Pull the thermostat body off  the thermostat base. Forcing
or prying on the thermostat will cause damage to the unit.
2. Place base over hole in wall and mark mounting hole
locations on wall using base as a template.
3. Move base out of  the way. Drill mounting holes. If  you
are using existing mounting holes and the holes drilled
are too large and do not allow you to tighten base snug-
ly, use plastic screw anchors to secure the base.
4. Fasten base snugly to wall using mounting holes shown
in Figure 1 and two mounting screws. Leveling is for
appearance only  and will not affect thermostat operation.
5. Connect wires to terminal block on base using
appropriate wiring schematic (see diagrams on next
page).
6. Push excess wire into wall and plug hole with a fire re-
sistant material (such as fiberglass insulation) to prevent
drafts from affecting thermostat operation.
7. Carefully line the thermostat up with the base and snap
into place.
Terminal Designation
Terminal Designation
Terminal Designation
Terminal Designation
Terminal Designation
Description
Description
Description
Description
Description
B  . . . . . . . . . . . . . . . . . . Changeover valve for heat pump energized constantly in heating
O  . . . . . . . . . . . . . . . . . . Changeover valve for heat pump energized constantly in cooling
Y  . . . . . . . . . . . . . . . . . . Compressor Relay
G  . . . . . . . . . . . . . . . . . . Fan Relay
RC  . . . . . . . . . . . . . . . . . . Power for Cooling
RH  . . . . . . . . . . . . . . . . . . Power for Heating
C  . . . . . . . . . . . . . . . . . . Common wire from secondary side of cooling
L  . . . . . . . . . . . . . . . . . . For Call for Service indicator for systems with diagnostic connection
6  . . . . . . . . . . . . . . . . . . Powered closed connection for 3-wire zone valve
W  . . . . . . . . . . . . . . . . . . Heat Relay
-  . . . . . . . . . . . . . . . . . . . Common (DC) for wired remote temperature sensor
S  . . . . . . . . . . . . . . . . . . Frequency signal from remote temperature sensor
+  . . . . . . . . . . . . . . . . . . Power (DC) to remote temperature sensor
TERMINAL DESIGNATION DESCRIPTIONS
TERMINAL DESIGNATION DESCRIPTIONS
TERMINAL DESIGNATION DESCRIPTIONS
TERMINAL DESIGNATION DESCRIPTIONS
TERMINAL DESIGNATION DESCRIPTIONS
Mounting
Hole
Mounting
Hole
Place Level
across
Mounting Tabs
(for appearance only)
Place Level
across
Mounting Tabs
(for appearance only)
+
S
-
6
L
W
Figure 1 – Thermostat Base Multi-Stage 1F97-1277
Figure 1 – Thermostat Base Multi-Stage 1F97-1277
Figure 1 – Thermostat Base Multi-Stage 1F97-1277
Figure 1 – Thermostat Base Multi-Stage 1F97-1277
Figure 1 – Thermostat Base Multi-Stage 1F97-1277
Rear view of thermostat
Rear view of thermostat
Rear view of thermostat
Rear view of thermostat
Rear view of thermostat