Siemens AC75 Manual De Usuario

Descargar
Página de 569
AC75 AT Command Set  
14.4 AT^SXSM
s
AC75_ATC_V01.002
Page 408 of 569
10/30/06
Confidential / Released
 
14.4
AT^SXSM Extended SIM Access
 extends 
 with additional SIM commands. 
All parameters of 
 are used as specified by GSM 11.1
. AC75 handles internally all required SIM
interface locking and file selection routines. 
AC75 may return error result code "+CME ERROR" if the command cannot be passed to the SIM, e.g. if no SIM
is inserted. However, errors related to SIM action are reported in 
 an
 parameters as defined in
Syntax
Parameter Description
136
RUN GSM ALGORITHM 
Start the authentication mechanism and cipher key generation on the SIM. It
runs the algorithms A3 and A8 using a 16 byte random number and the sub-
scriber authentication key Ki, which is stored in the SIM. 
Identifier for an elementary data file on SIM, if used by 
Parameter to be passed on by the AC75 to the SIM. 
Parameter to be passed on by the AC75 to the SIM. 
Parameter to be passed on by the AC75 to the SIM. 
If 
=136 (RUN GSM ALGORITHM): 
16 byte random number. 
Test Command
AT^SXSM=?
Response(s)
OK
Write Command
[, 
Response(s)
OK 
ERROR 
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
+
+
+
+
+
+
+
-
+
-
<command>
(num)
<fileID>
(num)
<P1>
(num)
<P2>
(num)
<P3>
(num)
<data>
(str)