Proxim Tsunami MP.11 and MP.11a CPN 65755B Manual De Usuario

Descargar
Página de 121
Tsunami MP.11and MP.11a Installation and Management 
CONFIGURATION RESTORE 
You can restore the configuration of the MP.11/a by downloading a configuration file.  The configuration 
file contains the configuration information of an MP.11/a.  
To download a configuration file through the Web Interface: 
1.  Set up the TFTP server as described in “TFTP Server Setup” 
 
2.  Access the MP.11/a as described in “Web Interface Overview”  
 
3. Click 
the 
Commands button and the Download tab. 
4.  Fill in the following details: 
Server IP Address <IP address TFTP server> 
File Name <configuration file name> 
File Type Config 
File Operation
 Download 
5. Click OK to start the file transfer. 
The MP.11/a downloads the configuration file. The TFTP server program should show download activity 
after a few seconds. When the download is complete and the system rebooted, the configuration is 
restored. 
SOFT RESET TO FACTORY DEFAULT 
If necessary, you can reset the MP.11/a to the factory default settings. Resetting to default settings 
means that you must configure the MP.11/a anew. 
To reset to factory default settings using the Web Interface: 
1. Click 
the 
Commands button and the Reset tab. 
2. Click 
the 
Reset to Factory Default button. 
The device configuration parameter values are reset to their factory default values. 
If you do not have access to the MP.11/a, you can use the procedure described in “Hard Reset to 
Factory Default” on page 106
as an alternative.  
Chapter 7.  Procedures 
 
105 
CPN 65755 
 
Issue Date:  August 2003