Proxim Tsunami MP.11 and MP.11a CPN 65755B Manual De Usuario

Descargar
Página de 121
Tsunami MP.11and MP.11a Installation and Management 
Proxim recommends you switch off the MP.11/a and the computer before connecting or disconnecting 
the serial RS-232C cable. 
To download an image file: 
1.  Set up the TFTP server as described in “TFTP Server Setup” 
  
2.  Start the terminal program (such as HyperTerminal), set the following connection properties, and 
then connect: 
COM port 
(for example COM1 or COM2, to which the MP.11 serial port is connected)
Bits per second 
9600 
Data bits 
Stop bits 
Flow control 
None 
Parity None 
 
3. 
Press the RESET button on the MP.11/a unit; the terminal program displays Power On Self Test 
(POST) messages.
 
4. 
When the
 
Sending Traps to SNMP manager periodically
 
message is displayed after 
about 30
 
seconds, press the
 
ENTER
 
key
5. 
The command prompt is displayed; enter the following commands
set ipaddr <IP address MP.11> 
set ipsubmask <subnet mask> 
set ipaddrtype static 
set tftpipaddr <IP address TFTP server> 
set tftpfilename
 <image file name> 
set ipgw
 <gateway IP address> 
reboot
 
 
For example: 
set ipaddr 10.0.0.12 
set ipsubmask 255.255.255.0 
set ipaddrtype static 
set tftpipaddr 10.0.0.20 
set tftpfilename
 image.bin 
set ipgw
 10.0.0.30 
reboot
 
 
The MP.11/a reboots and downloads the image file.  The TFTP server program should show download 
activity after a few seconds.  When the download is complete, the MP.11/a is ready for configuration. 
To access the MP.11/a see “Chapter 3.  Management Overview” 
  Note that the IP 
configuration in normal operation differs from the IP configuration of the Boot Loader. 
Chapter 7.  Procedures 
 
108 
CPN 65755 
 
Issue Date:  August 2003