Proxim Tsunami MP.11 and MP.11a CPN 65755B Manual De Usuario

Descargar
Página de 121
Tsunami MP.11and MP.11a Installation and Management 
2.  Select the MP.11/a for which you want to set the IP address and click Change.  The Change dialog 
window is displayed, as shown in the following window. 
 
3. Ensure 
that 
Static is selected as the IP Address Type and fill in the IP Address and Subnet Mask 
suitable for the LAN subnet to which the MP.11/a is connected. 
4. Enter 
the 
Read/Write Password (the default value is public) and click OK to confirm your changes.  
The respective MP.11/a reboots to make the changes effective. 
Note:  The asterisks displayed when you enter the password are a set number that does not 
necessarily equal the number of characters in the actual password string.  This is intended for 
added security. 
Dynamic IP Address with DHCP 
To obtain the IP address: 
1.  Run ScanTool on a computer connected to the same LAN subnet as the MP.11/a, or directly 
connected to the MP.11/a with a cross-over Ethernet cable. 
2.  Locate the MP.11/a for which you want to obtain the IP address.  You can find the current IP 
address in the IP Address column. 
The MP.11/a initially is set with a static IP address of 10.0.0.1. 
Chapter 3.  Management Overview 
 
21 
CPN 65755 
 
Issue Date:  August 2003