Tsunami MP.11and MP.11a Installation and Management 
2) Network 
IP Configuration 
The IP Configuration window lets you change the MP.11/a IP parameters.  These settings differ when 
the MP.11/a is in Router mode. 
Click the Configure button, the Network tab, and the IP Configuration sub-tab to view and configure 
local IP address information.  See “Setting the IP Address Manually” on page 20 for more information. 
 
If the device is configured in Bridge mode, you can set the following parameter: 
IP Address Assignment Type 
Select Static if you want to assign a static IP address to the MP.11; select Dynamic to have the 
device run in DHCP client mode, which gets an IP address automatically from a DHCP server over 
the network.  If you do not have a DHCP server or if you want to manually configure the IP settings, 
set this parameter to Static
When the MP.11/a is in Bridge mode, only one IP address is required.  This IP address also can be 
changed with ScanTool (see “Setting the IP Address Manually” on page 20).  In Router mode, both 
Ethernet and Wireless interfaces require an IP address. 
You can set the remaining parameters only when the IP Address Assignment Type is set to Static
IP Address 
The static IP address of the MP.11/a (default IP address is 10.0.0.1). 
Subnet Mask 
The mask of the subnet to which the MP.11/a is connected (the default subnet mask is 255.0.0.0). 
Default Router IP Address 
The IP address of the default gateway. 
Chapter 5.  Web Interface 
 
46 
CPN 65755 
 
Issue Date:  August 2003