mode (i.e.- not sending content to web viewers).  There are other password options that 
you can access from the QSX’s Web Administrator page.  These are described on 
Page 
30.
 
 
Note:  Web viewer sites do not necessarily need to participate in a phone call with the 
presenter in order to see content.  
 
Disconnecting Web Viewers 
When the QSX ends a presentation, you can disconnect the web viewers by ensuring the 
QSX is in Idle or Preview mode, then holding the Info button down for at least 4 seconds.   
If the QSX user re-initiates the presentation but hasn’t changed the password, the web 
viewers will need to refresh their browser and log in again.   
Note: A maximum of 10 web viewers can connect to each QSX during a meeting. 
 
Note:  If the QSX has a SoundStation or VTX 1000 phone attached, this configuration  
will override the stand alone operation.  Placing the SoundStation or VTX 1000 on-hook 
(i.e. - disconnecting the call) will drop all web viewer connections as well as H.323 calls 
and web viewer connections. 
 
QSX Connecting to Other QSX Systems 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
In calls between QSX systems, the systems automatically identify each other over the 
phone line using standards-based Low Profile Signaling Protocol (LPSP). The signal is 
embedded in the standard audio frequency band. When an audio call is placed, the QSX 
units connect to each phone and begin to communicate.  After the QSX systems identify 
each other, typically within 15-30 seconds, they automatically establish a H.323 content 
sharing channel over the LAN. One QSX system becomes the initial meeting controller 
and its IP address becomes the Meeting Web Address. At this point, web viewers can 
also join the meeting and receive content from the presenting QSX. 
 