Inverter operating status3 (FE42, FD42)
Operating status 3(status immediately before the occurrence of a trip):
Communication Number FE42
Operating status 3(current status):
Communication Number FD42
Bit
Function
0
1
Remarks
0
(Reserved)
1
Electric Power Counting
(FE76,FE77) status
Counting
Resetting
2
(Reserved)
3
(Reserved)
4
(Reserved)
5
(Reserved)
6
(Reserved)
7
(Reserved)
8
Acceleration/deceleration
pattern selection1
9
Acceleration/deceleration
pattern selection2
00:Acceleration/deceleration 1
01:Acceleration/deceleration 2
10:Acceleration/deceleration 3
Acceleration/ decelera-
tion 1 - 3 can be speci-
fied by combination of
two bits
10
(Reserved)
11
(Reserved)
12
Over-current stall level change
OC stall 1
OC stall 2
OC1:F601
OC2:F185
13
(Reserved)
14
(Reserved)
15
(Reserved)
„
 
Inverter operating status4 (FE49, FD49)
Operating status 4(status immediately before the occurrence of a trip):
Communication Number FE49
Operating status 4(current status):
Communication Number FD49
Bit
Function
0
1
Remarks
0
RY terminal output hold
OFF
Holding
1
OUT terminal output hold
OFF
Holding
2 to 15 (Reserved)