Toshiba TOSVERT VF-S11 Manual De Instrucciónes

Descargar
Página de 68
E6581222
61
■ Command 
parameters
For those parameters that contain data only in the RAM and not in the EEPROM, their data return to
initial values when the power is turned off, in failure resetting, or when standard shipment settings
are set.  Note that parameters without data storage in the EEPROMs will be written in the RAMs
only even if the command W (writing in EEPROMs and RAMs) is executed.
■ Commands                           NOTE : Data is expressed in decimal notation.
Communica-
tion
Num-
ber.(HEX)
Function
Adjustment Range
Min.
Setting
Unit
Initial
Value
Write
During
Operation
EEP
ROM
FA00
Command 1 (Communication)
*1
0 to 65535
0
yes
None
FA01
Operation frequency command
value (Communication) 
*1
0 to Max. frequency
()
0.01Hz
0
yes
None
FA03
Operation frequency command
value (Panel)
*2
Low-limit frequency
() to High-limit
frequency ()
0.01Hz
0
yes
Available
FA10
Panel key selection
*4
0 to 1
0
yes
None
FA11
External communication key
data
*4
0 to 65535
0
yes
None
FA20
Command 2 (Communication)
*1
0 to 65535
0
yes
None
FA26
Command 3 (Communication)
*1
0 to 65535
0
yes
None
FA50
Terminal output data
*3
0 to 65535
1
0
yes
None
FA51
Analog output data
*3
0 to 1023
(10-bit resolution)
1
0
yes
None
FA65
Select display by communica-
tion
*4
0 to 2
1
yes
Available
FA66
Numerical display data
*4
0-9999
1
0
yes
Available
FA67
Decimal point position
*4
0 to 2
0
yes
Available
FA68
LED data for unit 0
*4
0 to 3
0
yes
Available
FA70
ASCII display data 1
First digit from left
*4
0 to 127
100
(‘d’)
yes
Available
FA71
ASCII display data 1
Second digit from left
*4
0 to 255
65
(‘A’)
yes
Available
FA72
ASCII display data 1
Third digit from left
*4
0 to 255
116
(‘t’)
yes
Available
FA73
ASCII display data 1
Fourth digit from left
*4
0 to 127
65
(‘A’)
yes
Available
FA74
LED data for unit1
*4
0 to 3
0
yes
Available
FA75
ASCII display data 2
First digit from left
*4
0 to 127
48
(‘0’)
yes
Available
FA76
ASCII display data 2
Second digit from left
*4
0 to 255
48
(‘0’)
yes
Available
FA77
ASCII display data 2
Third digit from left
*4
0 to 255
48
(‘0’)
yes
Available
FA78
ASCII display data 2
Fourth digit from left
*4
0 to 127
48
(‘0’)
yes
Available
FA79
LED data for unit 2
*4
0 to 3
0
yes
Available
FA80
Block communication mode
*4
0 to 1
0
yes
Available
*1
: Enable the communication command or communication frequency setting before setting these
parameters are set.    Otherwise, the parameters will not function.    See “8.1 Command by com-
munication” for the method to enable them.
*2
: Note that the Communication Number for operation frequency command values (panel) is FA02
in the VF-S7 and VF-S9 series.
*3
: See “8.3 Control of input/output signals from communication” for the detail information.
*4