Wire the burner 
— R7184
Disconnect electrical power before installing or servic-
ing the burner.
Provide ground wiring to the burner, metal control en-
closures and accessories. (This may also be required to 
aid proper control system operation)
Perform all wiring in compliance with the National 
Electric Code ANSI/NFPA 70 (Canada CSA C22.1).
y
y
y
Electrical shock can cause severe personal in-
jury or death.
Electrical Shock Hazard
Install the burner and all wiring in accordance with the National 
Electrical Code and all applicable local codes or requirements.
Wire the burner in compliance with all instructions provided by 
the appliance manufacturer. Verify operation of all controls in 
accordance with the appliance manufacturer’s guidelines.
See  Figure 9 for a typical wiring diagram, with R7184 oil 
primary, for reference purposes only. 
Keep Service Access 
Covers Securely Installed
These covers must be securely in place to 
prevent electrical shock, damage from exter-
nal elements, and protect against injury from 
moving parts.  
All covers or service access plates must be in place at 
all times except during maintenance and service. 
This applies to all controls, panels, enclosures, switch-
es, and guards or any component with a cover as part 
of its design.  
y
y
Safety controls are designed and installed to provide 
protection.
Do not tamper with, or bypass any safety control.
If a safety control is not functioning properly, shut off 
all main electrical power and fuel supply to the burner 
and call a qualifi ed service agency immediately.
y
y
y
Tampering with, or bypassing safety controls 
could lead to equipment malfunction and result  
in asphyxiation, explosion or fi re. 
Do Not Bypass Safety 
Controls
Prepare the burner for 
start-up
This burner must be installed and prepared for start-up 
by a qualifi ed service technician who is trained and ex-
perienced in commercial oil burner system installation 
and operation.
Do not attempt to start the burner unless you are fully 
qualifi ed.
Do not continue with this procedure until all items in 
the “Prepare the burner for start-up” section have been 
verifi ed.  
Carefully follow the wiring diagrams, control instruc-
tion sheets, fl ame safeguard sequence of operation, test 
procedures and all appliance manufacturer’s directions 
that pertain to this installation.
If any of these items are not clear or are unavailable, 
call Beckett at 1-800-645-2876 for assistance.
y
y
y
y
y
Incorrect installation and mishandling of start-
up could lead to equipment malfunction and re-
sult in asphyxiation, explosion or fi re.
Professional Installation 
and Service Required
Figure 9. - Typical wiring
Legend
FD = Fused disconnect
LM = Limit controls
OP = Operating controls
PR = Oil primary controls
CC = Flame sensor, CAD 
Cell type
TR = Ignition transformer
M1 = Burner Motor
S1 = Oil Valve
T-T = 24-volt thermostat
F-F = CAD cell fl ame sensor 
terminals