Hitachi Flooring NT50AGF Manual De Usuario

Descargar
Página de 102
— 17 —
English
INSTALLING A FITTING
Before using the model NT50AGF Pneumatic Flooring Nailer, a 3/8” 
Thread Fitting must be installed.  The NT50AGF Pneumatic Flooring 
Nailer has an adapter installed to accept a 3/8” Thread fitting.  This 
provides the owner the advantage of installing the preferred Fitting 
of choice. (ie: Hitachi Fittings; Industrial (P/N 190051), Automotive 
(P/N 190071)). This allows the freedom to use any configuration of 
quick connect fitting with either a 3/8 NPT thread or a combination 
of a 1/4 NPT thread fitting and 3/8 – 1/4 NPT reducer.  Install the Fit-
ting into the supplied adapter and gently tighten.
CAUTION: Do not remove the installed adapter.  This adaptor pro-
vides connection of the Fitting of choice as well as protecting the 
integrity of the NT50AGF Pneumatic Flooring Nailer Body from inlet 
port damage.
IMPORTANT: The 
bottom hole of the 
NT50AGF that is 
plugged should 
NEVER be removed.   
If plug is removed,  
the NT50AGF Pneu-
matic Flooring Nailer 
will not perform cor-
rectly and serious 
damage may occur.
CHANGING FLOORING SHOES
Loosen or remove Flange Nuts (Ref. No. 33) with Wrench and 
unscrew the Shoe Screw (Ref. No. 50) to remove and change over 
from Tongue Nailing to Face Nailing Applications. Change from 
Face Nailing to Tongue Nailing by loosening or removing Flange 
Nuts (Ref. No. 33) with Wrench and Face Shoe Screw (Ref. No. 42).  
Always tighten the Shoe Screw (Ref. No. 50 or 42) before tightening 
the Flange Nuts (Ref. No. 33).
33
50
33
42